background image

1

1

2

2

3

3

4

4

A

A

B

B

C

C

D

D

Parts List

DESCRIPTION

QTY

ITEM

Antenna

1

1

Ground plate

1

2

MOUNT

1

3

NC #8 x 3/8" Philips Flat Head Screw

4

4

U-Bolt M8

2

5

Hex Nut M8

4

6

Flat Washer for M8

4

7

Lock Washer for M8

4

8

PAY ATTENTION

 

If edge A of mount is near connector -
connector will be farther from pole.
 
If edge B of mount is near connector -
connector will be closer to pole.
 

FIG. 1

PAY ATTENTION

 

Space C between ground plate item 2 & pole
depends on U-bolts' item 5 position on pole.
 
Space C may be 0.

FIG. 2

CHNG/REV

DESCRIPTION

ECN No.

DATE

APPROVED

DRAWN

 

 

 

 

 

 

            MOUNTING INSTRUCTION FOR ANTENNA MA-WO-UWB
                  WITH GROUND PLANE MG-370; MG-400 & MOUNT
 
1. Remove mount item 3 from antenna. (Screws of mount won't be used any more.)
2. Adjust ground plate item 2 with base of antenna so connector passes thru window
    in ground plate. Close mount & ground plate to antenna with items 4 (locktite
    recommended). (FIG. 1).
3. Put U-bolts item 5 on the pole. Adjust mount item 3 with U-bolts (FIG. 2).
4. Close U-bolts with fasteners items 6, 7, 8. Tighten nuts item 6 so they hold antenna.
    (Don't tighten finally.)
5. Adjust antenna as desirable. Evenly tighten nuts item 6 finally.
    Recommended fastening torque for each nut:
    10 N*m (100 kg*cm; 87 lb*in).

C

POLE

A

B

3

4

2

CONNECTOR

1

5

6

7

8

POLE

5

2

5

6

7

8

3