5.

 

Rinse the filter with clean water and allow

it to air-dry. 

DO NOT

 let the filter dry in

direct sunlight.

6. Reinstall the filter.

Repairing Refrigerant Leaks

 WARNING

If the refrigerant leaks, turn off the air

conditioner and any combustible heating

devices, ventilate the room and call your

dealer immediately. Refrigerant is both toxic

and flammable. 

DO NOT 

use the air

conditioner until the leak is repaired.

 

When the air conditioner is installed in a

small room, measures must be taken to

prevent the refrigerant concentration from

exceeding the safety limit in the event of

refrigerant leakage. Concentrated

refrigerant causes a severe health and safety

threat.

Refrigerant Leak Detection System (some 
models)

In the event of a refrigerant leak, the LCD

screen will display “EC” and the LED

indicator light will flash.

Preparation For Periods Of Non-Use

Maintenance after Extended Non-Use

 

1.

 

Remove any obstacles blocking the vents of

both the indoor and outdoor units.

2.

 

Clean the air filter and the front grille of the

indoor unit. Reinstall the clean, dry air filter in

its original position.

3.

 

Turn on the main power switch at least 12

hours prior to operating the unit.

Storing the Unit While Not In Use

1.

 

Run the appliance on FAN mode for 12 hours

in a warm room to dry it and prevent mold.

2.

 

Turn off the appliance and unplug it.

3.

 

Clean the air filter according to the

instructions in the previous section. Reinstall

the clean, dry filter before storing.

4. Remove the batteries from the remote control.

3.

 

Hold the tabs of the frame,and remove the

4 claws. (The special function filter can be

washed with water once every 6 months. It

isrecommended that you replace it once

every 3 years.)

4.

 

Clean the air filter by vacuuming the surface

or washing it in warm water with mild

detergent.
A.

  

If using a vacuum cleaner, the inlet side

should face the vacuum.

Fig. 4.4

Fig. 4.3

B.

  

If using water, the inlet side should face

down and away from the water stream.

Fig. 4.5

Special function filter

Summary of Contents for Comfort Aire Century B-VMH12FU-1

Page 1: ...OWNER S MANUAL Console Unit Models B VMH12FU 1 517 787 2100 www marsdelivers com...

Page 2: ...Owner s Manual B VMH12FU 1 2 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 3: ...Owner s Manual B VMH12FU 1 3 Indoor Unit Parts and Major Functions 6 Manual Operations 8 Table of Contents Owner s Manual SAFETY FIRST Safety Precautions 5 1 2 3...

Page 4: ...re and Maintenance 9 Unit Maintenance 9 How to Clean the Air Filter 9 Repairing Refrigerant Leaks 10 Preparation for Periods of Non use 10 Troubleshooting 11 Common Problems 11 Troubleshooting Tips 12...

Page 5: ...heat producing appliances to cold air or place them under the indoor unit This may cause incomplete combustion or deformation of the unit due to the heat After long periods of usage check the indoor u...

Page 6: ...peration If the air conditioner is used under different conditions it may malfunction or become less efficient Drain hose Refrigerant connecting pipe Display panel Air inlet with air filter in it Air...

Page 7: ...oom DO NOT place objects near the air inlet and outlet of the unit Set a timer and use the built in SLEEP ECONOMY mode if applicable If you don t plan to use the unit for a long time remove the batter...

Page 8: ...unit turns off and the remote control is re enabled Infrared receiver Timer indicator PRE DEF pre heating defrost indicator Operation indicator Adjusting Air Flow Direction CAUTIONS Do not try to adj...

Page 9: ...ally treated cloths to clean the unit DO NOT use benzene paint thinner polishing powder or other solvents to clean the unit They can cause the plastic surface to crack or deform DO NOT wash the unit u...

Page 10: ...nded Non Use 1 Remove any obstacles blocking the vents of both the indoor and outdoor units 2 Clean the air filter and the front grille of the indoor unit Reinstall the clean dry air filter in its ori...

Page 11: ...EF Pre heating Defrost indicators are lit up the outdoor temperature is too cold and the unit s anti cold wind is activated in order to defrost the unit In Cooling only Models If the Fan Only indicato...

Page 12: ...s emitted from either the indoor or outdoor unit The unit may accumulate dust during extended periods of non use which will be emitted when the unit is turned on This can be mitigated by covering the...

Page 13: ...term use Check for leaks re seal if necessary and top off refrigerant The unit starts and stops frequently There s too much or too little refrigerant in the system Check for leaks and recharge the sy...

Page 14: ...lfunction 9 Off N A 9 Other twin model malfunction 10 Off N A 10 Overload protection 1 On F0 11 Outdoor temperature sensor error 2 On F 1 12 Outdoor condenser pipe sensor error 3 On F2 13 Discharge ai...

Page 15: ...warranty period Without this proof the express warranty begins on the date of shipment from the factory Please visit www marsdelivers com to register your new product REMEDY PROVIDED BY THE LIMITED EX...

Page 16: ...DOOHU LV UHVSRQVLEOH IRU YHULI LQJ GLPHQVLRQDO GDWD RQ WKH DFWXDO SURGXFW SULRU WR EHJLQQLQJ DQ LQVWDOODWLRQ SUHSDUDWLRQV QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXFW SHUIRUPDQ...

Reviews: