For X-13 Motor Operation:

First remove power from the HVAC system and set

thermostat to OFF.

¿

Remove the GREEN/YELLOW and WHITE lead power

wire harness from the Azure motor.

¡

Plug the factory power harness into Azure

.

¬

Connect BROWN & WHITE auto sizing harness to

system 24V and Common.

(This is a temporary connection for auto sizing the

motor).
Apply power to the HVAC system.  Make certain to

close the blower housing, and open all supplies and

returns.  Also make certain the air filter is clean.  Motor

will run for approximately 2 minutes and stop to

indicate the auto sizing process is complete.  

When motor comes to a complete stop, remove power.

NOTE:  MOTOR MUST COME TO A COMPLETE

STOP BEFORE POWER IS REMOVED OR THE

MOTOR MAY NOT ACCEPT THE PROGRAM.  

Disconnect and remove the BROWN & WHITE auto

sizing harness.

ƒ

Connect the 24V speed taps as desired to the

thermostat board for heat/cool.

Apply power to the HVAC system and test full

operation including airflow.

Quick Reference Guide

MARS Motor No. 10860/10861

Azure

Set-Up

(Numbers below correspond to connections in diagram on reverse side)

¿

Set motor voltage:  230V w/RED jumper open, 115V w/RED jumper connected (closed)

¡

Set motor rotation:  CCWLE w/WHITE jumper open, CWLE w/WHITE jumper connected (closed)

¬

Set motor mode of operation:  X-13 w/BLUE jumper open, PSC w/BLUE jumper connected (closed)

For PSC Motor Operation:

First remove power from the HVAC system and set thermostat to OFF.

¿

Connect WHITE NEUTRAL lead to system Neutral.

¡

Connect GREEN/YELLOW GROUND lead to system Ground.

¬

Connect BROWN & WHITE harness to system 24V and Common.

(This is a temporary connection for auto sizing the motor)
Connect RED speed tap 5 to system L1.

(This is a temporary connection for auto sizing the motor)
Apply power to the HVAC system.  Make certain to close the blower

housing, and open all supplies and returns.  Also make certain the air

filter is clean.  Motor will run for approximately 2 minutes and stop to

indicate the auto sizing process is complete.  

When motor comes to a complete stop, remove power.  NOTE:  MOTOR

MUST COME TO A COMPLETE STOP BEFORE POWER IS

REMOVED OR THE MOTOR MAY NOT ACCEPT THE PROGRAM.

BECAUSE THE SYSTEM HAS POWER, DO NOT BE ALARMED IF

THE BLOWER RESTARTS APPROXIMATELY 30 SECONDS AFTER

THE AUTO SIZE IS COMPLETE.

Disconnect the BROWN & WHITE harness and the RED speed tap 5.

ƒ

Connect the 115V speed taps as desired to the HVAC system control

board for Heat/Cool.

Apply power to the HVAC system and test full operation including airflow

test.

Note:  For low speed constant fan operation, see Azure

installation manual.

This guide is intended to be a quick reference and should be left with the equipment for future reference. You

must read the installation manual prior to installation.

To prevent electric shock, personal injury, or death, turn off the electric power at the disconnect or main service panel prior to making any

electrical connections.