SOLO
–
IDEA
COMPACT GSM DOOR ENTRY UNIT WITH 1, 2 or 4 CALL BUTTONS
INSTALLATION MANUAL
Version: Solo-IDEA - Installation-Manual
_V1_0-11052017.doc
Valid from SW release: “
SOLO_EF_B_ON_PCK_20170412_v_3_4_3
”.
Page 1: ...SOLO IDEA COMPACT GSM DOOR ENTRY UNIT WITH 1 2 or 4 CALL BUTTONS INSTALLATION MANUAL Version Solo IDEA Installation Manual_V1_0 11052017 doc Valid from SW release SOLO_EF_B_ON_PCK_20170412_v_3_4_3 ...
Page 2: ...ITY PSQ 25 10 4 RECEIVE TELEPHONE NUMBERS PTN 25 10 5 RECEIVE LINKS PLN 25 10 6 RECEIVE INPUT PARAMETERS PIN 25 10 7 RECEIVE INPUT FILTER VALUE PID 25 10 8 RECEIVE OUTPUT FILTER VALUE POD 26 10 9 RECEIVE DELAY BEFORE DIAL VALUE PDD 26 10 10 RECEIVE ACCESS TELEPHONE NUMBERS PSL 26 10 11 RECEIVE OUTPUT PARAMETERS POS 26 10 12 RECEIVE ALL PROGRAMMED SMS MESSAGES P 26 10 13 RECEIVE SET UP PARAMETERS V...
Page 3: ...reporting example 10 Table 5 DTMF control example 11 Table 6 Output management parameters 12 Table 7 Output management parameters example 12 Table 8 SL parameter 13 Table 9 SL example 13 Table 10 Prepaid card validity parameters 14 Table 11 Credit example 15 Table 12 Set up parameters 17 Table 13 Set up parameters example 18 Table 14 Message parameters 18 Table 15 Message parameters example 19 Tab...
Page 4: ...sting is in progress USE SENSIBLY Use only in the normal position as explained in the product documentation Do not touch the antenna unnecessarily 2 INTRODUCTION SOLO IDEA is a simple GSM intercom communication system that is designed to ensure low cost reliable and single box solution for intercom application It is designed for unlimited range wire free GSM intercom and Caller ID recognition CLIP...
Page 5: ...insert the SIM Connect inputs and outputs to SOLO IDEA Connect the antenna to antenna connector Connect power cable to SOLO IDEA device Connect device to source power supply voltage Wait until LED3 display is turned ON Yellow and LED1 Blue starts flashing This is set in around 30 45 seconds SOLO IDEA unit is now ready to operate IMPORTANT Before sending any SMS commands to SOLO IDEA device SOLO ID...
Page 6: ...onnection Yellow LED is flashing with short pulse ON and a long pulse OFF 6 CLEAR ALL PROGRAMMED DATA FROM SOLO IDEA This is highly recommended when a SIM card you are going to use for the SOLO IDEA is not new and it already has some data stored in the phone book memory By sending this SMS to SOLO IDEA all programmed parameters and numbers are cleared SDCLR After sending SMS you should wait at lea...
Page 7: ...r source for door electric lock 8 PROGRAMMING SOLO IDEA SOLO IDEA device supports different types of programming With direct USB connection USB to Mini USB cable with the use of configuration software EasySet running on PC Remotely by sending text messages SMS commands Remotely with Android application or with IOS application Remotely with Web server application www easyset eu NOTES To receive con...
Page 8: ...rm input can be on only used as normal open N O triggered with GND When you need the input feedback information it is possible to receive SMS when input returns from alarm to normal position To receive the return SMS use IN setting 4 IN 0 Normal Open triggered with negative voltage GND IN 4 IN 0 input reset SMS INPUT 1 2 GND INPUT 1 2 N O Contact N O Contact Figure 2 Input Connection diagram 9 1 1...
Page 9: ...valid for 10 second to trigger the alarm ID2 0 Input 2 has to be valid for 0 5 second to trigger the alarm DD1 0 Reporting of the alarm on input 1 is delayed by 0s DD2 15 Reporting of the alarm on input 1 is delayed by 15s Table 2 IN ID DD parameters example Remote programming by SMS IN1 0 IN2 4 ID1 10 ID2 0 DD1 0 DD2 15 9 1 2 REMOTE REPORTING ALARM EVENTS Parameters used to define the way to repo...
Page 10: ...5 LN5 Periodic test SMS No linking TN1 TN5 LN6 SIM card refill No linking TN1 TN5 LN7 NAC list No linking TN1 TN5 see note LN8 Log status No linking TN1 TN5 LOT Time out for GSM connection Table 3 Remote alarm reporting parameters NOTE When telephone number calling or messaging SOLO IDEA is not on the CLIP list not acknowledge event occurs NAC The telephone number responsible for this event can be...
Page 11: ...in voice connection to support DTMF output control Example DTMF combination Description 00 Deactivate ALL outputs 01 Activate ALL outputs 11 Activate output 1 10 Deactivate output 1 if in latching mode 21 Activate output 2 20 Deactivate output 2 if in latching mode Table 5 DTMF control example 9 2 OUTPUT MANAGEMENT SOLO IDEA supports the possibility to report alarms from inputs and any other event...
Page 12: ...1 direct link to outputs OD2 Input 2 direct link to outputs OD3 NAC direct link to outputs OP1 Invert control for output 1 OP2 Invert control for output 2 Table 6 Output management parameters Example Direct programming on the SIM card SOLO IDEA PROGRAMMING TABLE Name Number Description OS1 1 Bistable toggle mode OS2 14 Monostable pulse mode 14s pusle OD1 1 Input 1 activates output 1 OD4 2 Input 2 ...
Page 13: ...stored under parameters TN1 to TN3 have access to unit SL 4 Numbers stored under parameters TN1 to TN4 have access to unit SL 5 Numbers stored under parameters TN1 to TN5 have access to unit Table 8 SL parameter Example Direct programming on the SIM card SOLO IDEA PROGRAMMING TABLE Name Number Description SL 3 Numbers stored under parameters TN1 to TN3 have access to unit Table 9 SL example Remote...
Page 14: ...icated to Italian TIM mobile provider CC3 This method is dedicated to Italian Vodafone mobile provider 9 4 1 3 CREF CTIM CVODA parameters Parameters are used to find the credit value of the prepaid SIM card Strings under these parameters are used to pars the replay message from the GSM provider CREF Pars string for the replays received from CC1 number CVODA Pars string for the replays received fro...
Page 15: ...conceal the telephone number of the SOLO IDEA device The default value is set to 1 which means that the number is displayed 9 5 2 ESC parameter Parameter is used to define the input used to cancle the outgoing call from the SOLO IDEA device 9 5 3 UDC parameter Parameter is used to synchronise SOLO IDEA clock to GSM network clock User must enter here the number of the SOLO IDEA SIM card Telephone n...
Page 16: ...rameter value is defined in hours Example To receive first test SMS at 20 00h TSTT value must be set to 20 NOTE By setting TSTT 0 this function is disabled 9 5 7 MNF parameter When it is necessary to fix the GSM network to one provider the user can use the MNF parameter The MNF parameter switches automatic network searching to manual Example MCC MNC code for Simobil is 29340 Mobitel is 29341 TIM i...
Page 17: ...an 2 Slovenian 3 Croatian 4 Dutch 5 German 6 Spanish 9 5 14 BUZ parameter Parameter is used to control buzzer functionality on SOLO IDEA Buzzer is used to audio support some events on SOLO IDEA device 9 5 15 Table of parameters Name Comment UDC Tel number of SOLO IDEA device ESC Input used as cancel button RAN Auto answer ring number HTN Hidden telephone number TST SMS test time out TSTT Periodic ...
Page 18: ...h but it is possible to change language with LNG parameter Each message is built from 3 parts and user can write the first User Location and the second alarm event part of the message Unit adds the third part alarm event description automatically Language of the 3rd part may be changed by LNG parameter The message is stored in the SIM phone book so you should add any number for correct operation 1...
Page 19: ...OM Intercom functionality is supported by a set of parameters used to tweak the functionality to each user needs For each button SOLO IDEA incorporates a group of parameters There are up to 4 groups of parameters IMPORTANT SOLO IDEA is capable of supporting up to 4 call buttons The current version is equipped with 1 2 or 4 call buttons so GROUP A GROUP B GROUP C and GROUP D are all described in th...
Page 20: ...uto self select function 9 7 4 Time zone Time zone support When both time limits are sets TZSx and TZEx time zone functionality is ON When the current time is in the limits of the time zone parameters the button event calls the number from xTN1 to xTN4 else button event calls xTN5 9 7 4 1 TZSx parameter Parameter is used to configure the start time for the time zone functionality 24h time format 9...
Page 21: ...for DTMF number to send TZSC Button 3 time zone start period TZEC Button 3 time zone end period DTN1 Button 4 Telephone number 1 DTN2 Button 4 Telephone number 2 DTN3 Button 4 Telephone number 3 DTN4 Button 4 Telephone number 4 DTN5 Button 4 Telephone number 5 RTND Button 4 time out control for voice connection SDND Button 4 DTMF number to send SDDD Button 4 delay for DTMF number to send TZSD Butt...
Page 22: ...rol the output The number not on CLP list is not able to control the output using clip functionality 9 8 5 Table of parameters Name Comment CLPEN Enable CLIP functionality CLPOU Control output pin when CLIP event CLPI CLIP input activation condition CLP1 CLIP number 1 CLP1000 CLIP number 1000 Table 18 CLIP parameters Example Direct programming on the SIM card SOLO IDEA PROGRAMMING TABLE Name Numbe...
Page 23: ...ing is OFF LOGI 1 Logging in internal memory LOGI 2 Logging to USB interface 9 9 3 ALC parameter Parameter is used to control behavior when log on SOLO IDEA is full User can select between auto log clear or manual clear of log ALC 0 Automatically delete buffer when memory is FULL ALC 1 Memory buffer must be deleted manually when it is FULL 9 9 4 Table of parameters Name Comment LOGN Number of log ...
Page 24: ...ES command Command is used to manually restart GSM module on SOLO IDEA device 9 10 6 SSRES command Command is used to manually restart SOLO IDEA device 9 10 7 Table of parameters Name Comment ORC1 Control of output 1 ORC2 Control of output 2 SDCLR Delete all SIM content LCRL Delete log on SOLO IDEA device MRES Manual reset of GSM module SSRES Manual reset of SOLO IDEA device Table 22 SMS commands ...
Page 25: ... to SOLO IDEA you receive SMS messages with signal quality SOLO IDEA device is connected to network PSQ 10 4 RECEIVE TELEPHONE NUMBERS PTN By sending this command to SOLO IDEA you receive SMS message with all currently programmed telephone numbers TN1 TN5 PTN 10 5 RECEIVE LINKS PLN By sending this command to SOLO IDEA you receive SMS message with all currently programmed links LN1 LN8 PLN 10 6 REC...
Page 26: ...ceive SMS message with all currently programmed Outputs parameters OS1 OS2 POS 10 12 RECEIVE ALL PROGRAMMED SMS MESSAGES P By sending this command to SOLO IDEA you receive SMS message with all currently programmed alarm SMS messages 0 4 P 10 13 RECEIVE SET UP PARAMETERS VALUE PPA By sending this command to SOLO IDEA you receive SMS message with all currently programmed Setup parameters TST MNF PPA...
Page 27: ... SDNB SDDB TZSB TZEB PDEB 10 18 RECEIVE INTERCOM BUTTON 3 PARAMATERS PDEC By sending this command to SOLO IDEA you receive SMS message with all currently programmed button 1 group parameters CTN1 CTN2 CTN3 CTN4 CTN5 RTNC SDNC SDDC TZSC TZEC PDEC 10 19 RECEIVE INTERCOM BUTTON 4 PARAMATERS PDED By sending this command to SOLO IDEA you receive SMS message with all currently programmed button 2 group ...
Page 28: ...ll parameters from the SIM card MRES 10 23 RECEIVE STATUS OF INPUTS INS By sending this command to SOLO IDEA you receive SMS message with current input state INS 10 24 RECEIVE SOLO IDEA LOG By sending this command to SOLO IDEA you receive SMS message with log on SOLO IDEA device PLOG NOTE User can use PLOG x y to define the number of logs to be printed x start event y end event Example PLOG 1 30 P...
Page 29: ...N2 38643364850 If you would like to receive confirmation SMS write before SMS command TN1 040713470 TN2 38643364850 Return SMS from SOLO IDEA is TN1 040713470 TN2 38643364850 NOTE You can use the same programming procedure for all parameters It is also possible to change different parameters with one SMS Consider that the SMS message should not be longer than 160 characters included space characte...
Page 30: ...SMS text link to tel numbers LN6 Empty SIM card refill link to tel numbers LN7 Empty NAC link to tel numbers LN8 Empty LOG full link to tel numbers ID1 1 Input 1 delay filter on input ID2 120 Input 2 delay filter on input DD1 0 Input 1 delay before dialing DD2 0 Input 2 delay before dialing SL 0 Security level 0 User Location SMS main head text 1 Input1 SMS input 1 text 2 Input2 SMS input 2 text C...
Page 31: ...l output pin when CLIP event CLPI 0 CLIP input activation condition CLP1 Empty CLIP number 1 CLP1000 Empty CLIP number 1000 ATN1 Empty Button 1 Telephone number 1 ATN2 Empty Button 1 Telephone number 2 ATN3 Empty Button 1 Telephone number 3 ATN4 Empty Button 1 Telephone number 4 ATN5 Empty Button 1 Telephone number 5 RTNA 25 Ring time Button 1 SDNA 0 DTMF number to send SDDA 0 Delay for DTMF to se...
Page 32: ...mber 1 DTN2 Empty Button 4 Telephone number 2 DTN3 Empty Button 4 Telephone number 3 DTN4 Empty Button 4 Telephone number 4 DTN5 Empty Button 4 Telephone number 5 RTND 25 Ring time Button 4 SDND 0 DTMF number to send SDDD 0 Delay for DTMF to send TZSD 0 Time zone start interval TZED 0 Time zone end interval PIN1 Empty PIN access code 1 PIN1000 Empty PIN access code 1000 SPINO Empty Control SPIN re...
Page 33: ...ints OSx parameters P Prints x parameters PPA Prints various setup parameters PCLP Prints CLIP parameters PLOG Prints log of the SOLO IDEA PCREF Prints credit pars parameters PCN Prints credit request numbers PCC1 Prints credit for SOLO IDEA universal request PCC2 Prints credit for SOLO IDEA TIM Italy PCC3 Prints credit for SOLO IDEA VODAFONE Italy INS Prints status of the inputs PORC Prints contr...
Page 34: ... 106 89 mm Unit dimensions 1 and 2 buttons 156 x 116 x 70 51 mm Call buttons Up to 4 External Antenna 1 Weight Approx 1000 gr Alarm inputs 2 Alarm outputs relay 2 12V DC Aux Power Supply output Y max 100 mA 12 0 20 0 V AC or 12 0 24 0 V DC Power Supply input Y Anti tamper protection optional 15 CONTACTS MARS COMMERCE d o o MIRKA VADNOVA 19 4000 KRANJ SLOVENIA TEL 00 386 4 280 74 00 E MAIL info mar...