TECHNICAL DATA
Standard
EN 14604-2005
/AC:2008
Operating voltage
9 VDC (for smoke detector)
4.5 VDC (for wireless transmitter, 3 x 1.5 V
batteries)
Power consumption in operation
Smoke detector,
inactive: ≤ 10 µA
Smoke detector, active: ≤ 20 µA
Wireless transmitter, inactive: ≤ 230 µA
Wireless transmitter, active: ≤ 4 µA
Sound level for alarm
≥ 85 dB/3 m
Status light, alarm
Red LED
Status light, connected/learn mode
Red/green LED
Frequency
433
.92 MHz
Transmitting range
Free field: ≤ 60 m
Operating temperature
-10 to 40°C
Ambient air humidity:
≤ 95% RH (non
-condensing)
Low battery level indicator:
Smoke detector: < 7.35 V
A short audio prompt is given at 43 second intervals
Wireless
transmitter: < 3.3 V
A short audio prompt is given at 60 second intervals
DESCRIPTION
•
Photoelectric smoke detection
•
High sensitivity
•
Low power consumption
•
Can be connected to unlimited number of other units
Dimensions