Marq Gamut PAR H7 Service Manual Download Page 5

No any

response

Plug in the

power cable

or

try another cable

If not power cable no

problem, please open the

back cover to check

power

supply

Indicator light on power

supply light up.

Indicator light on power

supply not light up.

Main board(display board)

damage

Fusing or wires from socket to power supply loose

Indicator light on power

supply flash

Power supply damage

Power supply damage

Some color die

1. check the corresponding color’s sensor

6075

on main board. Use multi

meter to check if voltage exist on the first and third

foot. If no voltage, then change this sensor or the whole board

2. If

6075

exist voltage, check corresponding color’s sensor

LM317S

on LED board. Use multi

meter to check if voltage exist

on the first and third foot. If no voltage, then change this sensor.

3. If

LM317S

and

6075

existing voltage

,

check the solder on the led foot, weld the corresponding color’s led foot.

Out of control

Change the

100ohm resistance

on main board. If problem still exist, then change the sensor

75176

or change the main board

No memory

Change the sensor

ATML HXX64DH

on main board. Or change the whole main board.

If power supply no

problem, please check

program IC

on main board

Use multi

meter to check if 24V voltage exist on the

terminal for main board power

supply

. If no 24V, change the

program IC

or change whole main board

QP05_GamutPARH7 Troubleshooting Guidelines

Summary of Contents for Gamut PAR H7

Page 1: ...ecipient you are hereby notified that any review dissemination distribution or duplication of this document is strictly prohibited If you are not authorized please contact Marq and destroy all copies...

Page 2: ...anual shall be solely your responsibility and Marq shall have no liability for any such repairs or service work All such service or repairs are performed at the sole risk of the person performing the...

Page 3: ...WITH ANY NUMARK DISTRIBUTOR OR AUTHORIZED REPAIR SERVICE CENTER IN THE PROVISION OF REPAIR SERVICES OR TO BE OR MAKE REPAIRS AS AN AUTHORIZED SERVICE CENTER ALL REPAIRS DONE BY ANY ENTITY OTHER THAN...

Page 4: ...heat registers radiators or other heat producing equipment 7 Ventilation When installing the product make sure that the product has adequate ventilation Improperly ventilating the product may cause o...

Page 5: ...board 2 If 6075 exist voltage check corresponding color s sensor LM317S on LED board Use multi meter to check if voltage exist on the first and third foot If no voltage then change this sensor 3 If LM...

Page 6: ...or incompletely display If led light up but no display or incompletely display change the Digital Tube or change the whole main board display board No response of active function Check if MENU functio...

Page 7: ...Menu buttons Sensors ATML HXX64DH Digital tube Program IC Sensors 6075 there is marking for each color Terminal for 100ohm resistance microphone Sensor 75176 Sensor LM317S LM2576T 12V...

Page 8: ...1 12 13 14 15 16 17 18 19 20 1 21 2 22 1 3 2 1 1 1 7 7 1 1 4 4 1 1 1 1 1 1 1 1 1 1 4 binder brace LED board power supply aluminum house assistant part heatsink dummy plate fan display display holder s...

Page 9: ...WM12 17 P1 0 RXD1 PWM0 18 P1 1 TXD1 PWM1 19 P1 2 PWM2 20 P1 3 PWM3 21 P1 4 ADC0 PWM4 22 P1 5 ADC1 PWM5 23 P1 6 ADC2 PWM6 24 P1 7 ADC3 PWM7 25 P2 0 PWM13 26 P2 1 PWM14 27 VCC 28 3IC1 MCU RXD TXD RST 5V...

Page 10: ...QP05 Packing Procedure 1 2...

Page 11: ...3 4...

Page 12: ...5 6...

Page 13: ...7 8...

Reviews: