Marmitek LMM32 User Manual Download Page 6

LMM32 

SIGNAL RANGE 

Range of Marmitek X-10 signals over the Power Line 
and how to increase the range. 

The Marmitek X-10 System is based on power line 
communication. The range of the Marmitek X-10 signals 
very much depends on the local circumstances. On average 
the range is a cable length of 80 meters.  

If you have difficulties with the range of your 
Marmitek X-10 signals, please pay attention to the 
following facts: 

1. When more than one phase is used for your electrical 
system, it is necessary to couple these phases for the 
Marmitek X-10 signals. For coupling you can use FD10 
Phase Couplers/Filters. You only need to install a Phase 
Coupler/Filter when your wall outlets and light switches 
are divided over more than one phase (more than one 
group is no problem). For bigger buildings or longer 
distances we advice you to use an active repeater instead 
of passive FD10’s. 
2. It is possible that Marmitek X-10 signals are attenuated 
by devices and lights which are connected to the power 
line. In a normal home situation this effect is negligible 
(the Marmitek X-10 system is using active gain control to 
eliminate the effects). However, it is possible that a 
particular device in your house is attenuating the signals so 
much that the range of Marmitek X-10 signals is decreased 
significantly. When you have range problems, it is wise to 
try to locate the device which is attenuating the signals 
simply by unplugging devices from the power line, and 
testing the differences in range for your Marmitek system. 
When e.g. your conclusion is that e.g. your computer 
monitor is attenuating the signal, you can use a FM10 

Summary of Contents for LMM32

Page 1: ...USER MANUAL LMM32 20416 20111019 LMM32 ALL RIGHTS RESERVED MARMITEK LMM32 Dimmer Micromodule 2 load...

Page 2: ......

Page 3: ...ENTS 2 SAFETY WARNINGS 3 HOW DOES MARMITEK X 10 WORK 4 ADRESSES 4 SIGNAL RANGE 5 TWO LOAD DIMMER MICRO MODULE 7 FUNCTIONS 7 INSTALLATION 9 PROGRAMMING 10 FREQENTLY ASKED QUESTIONS 11 TECHNICAL DATA 13...

Page 4: ...light sources In case of improper usage or if you have altered and repaired the product yourself all guarantees expire Marmitek does not accept responsibility in the case of improper usage of the pro...

Page 5: ...Modules 3 Transmitters Wireless components like remotes The signals of these components will be received by a controller with transceiver functionality IRRF 7243 TM13 CM15Pro The Transceiver will tran...

Page 6: ...d over more than one phase more than one group is no problem For bigger buildings or longer distances we advice you to use an active repeater instead of passive FD10 s 2 It is possible that Marmitek X...

Page 7: ...rces than your Marmitek X 10 Controllers However it is possible that the Marmitek X 10 signals are disturbed by e g baby phones which are in TALK mode continuous transmission When these kind of signal...

Page 8: ...Remote control On Off and Dim Suitable for 230V and low voltage lighting with a transformer including halogen lighting Remote control via the mains using Marmitek X 10 Commands and with one or more mo...

Page 9: ...trolling low energy light bulbs and tube lighting An Appliance module should be used for these devices Phase and Neutral have to be available before the module can be installed Small enough 43 25 47 1...

Page 10: ...uilt in module to the double standard rocker switch Connect the thin Black Green and Yellow wires of the built in module to the double 1 way momentary switches normally open contacts Position the Micr...

Page 11: ...ule needs to be set to the program mode Press and hold the Program button for 5 seconds indicator light flickers once the controlled light Turns ON means entering Program mode Then you transmit the ad...

Page 12: ...t your incoming mains My modules will not respond to my controller Make sure that the House Code on all Modules and Controllers are set to the same House Code A P My modules will not react to my remot...

Page 13: ...nt signals to be disturbed when more than one transceiver is transmitting The Transceivers will wait for a quite power line before transmitting their data To prevent your Marmitek X 10 System to becom...

Page 14: ...DIM BRIGHT Extended Dim Input switch 1 way standard rocker switch ON OFF 1 way momentary switch normally open contact ON OFF DIM Use in 3 phase installation FD10 3x or FKX40 necessary Connections Wire...

Page 15: ...gular household waste streams It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authori...

Page 16: ...imation of the laws of the Member States relating to electromagnetic compatibility Directive 2006 95 EC of the European Parliament and of the Council of 12 December 2006 on the harmonisation of the la...

Page 17: ...tent including but not limited to model numbers software audio video text and photographs rests with Marmitek B V Any use of the Content but without limitation distribution reproduction modification d...

Page 18: ...LMM32 17...

Page 19: ...MARMITEK 18...

Page 20: ......

Reviews: