background image

Model No. MWUH

Horizontal / Vertical Unit Heater

(Field Adjustable from 1.9KW @ 208V to 5KW@ 240V

WARNING 

Dear Owner,

Congratulations!  Thank you for purchasing this new heater manufactured by a division of Marley
Engineered Products.  You have made a wise investment selecting the highest quality product in the heat-
ing industry.  Please carefully read the installation and maintenance directions shown in this manual.
You should enjoy years of efficient heating comfort with this product from Marley Engineered Products...
the industry’s leader in design, manufacturing, quality and service.

... The Employees of
Marley Engineered Products

Read Carefully 

These instructions are written to help

you  prevent  difficulties  that  might  arise  during  installation
of  heaters.  Studying  the  instructions  first  may  save  you
considerable time and money later. Observe the following
procedures,  and  cut  your  installation  time  to  a  minimum.

TO REDUCE RISK OF FIRE, ELECTRIC SHOCK OR HEATER FALLING:

1.

Use minimum 60° copper wire only.

2.

Heater  air  flow  must  be  directed  parallel  to,  or  away  from,
adjacent walls.

3.

Observe wall, floor, and ceiling clearance requirements.

4.

All wiring must conform to national and local electrical codes
and  the  heater  must  be  grounded  as  a  precaution  against
possible  electrical  shock.  Heater  circuit  must  be  protected
with proper fuses. See Table 1 on page 3.

5.

The mounting structure and the anchoring hardware must be
capable of reliably supporting the weight of the heater and, if
used, the mounting bracket.

6.

All electrical power must be disconnected at the main service
box  before  installing,  inspecting,  cleaning  or  servicing  the
heater.  This  is  a  precaution  to  prevent  possible  electrical
shock.

7.

This heater is not suitable for use in hazardous locations as
defined  by  the  National  Fire  Protection Association  (NFPA).
This heater has hot and arcing (sparking) parts inside. Do not
use in areas where gasoline, paint, or flammable liquids 
are used or stored.

8.

This heater is not suitable for use in corrosive atmospheres
such as marine, green houses or chemical storage areas.

9.

This heater must be mounted at least 6 feet (1829 mm) off the
floor.

10. This  unit  only  operates  on  240  or  208  volts  (AC),  60Hz.

Improper  installation  or  failure  to  follow  the  procedures  out-
lined in this instruction manual can result in serious electrical
shock. 

Installation & Maintenance Instructions

SAVE THESE INSTRUCTIONS

!

FILE #E21609

1

Summary of Contents for MWUH

Page 1: ...ceiling clearance requirements 4 All wiring must conform to national and local electrical codes and the heater must be grounded as a precaution against possible electrical shock Heater circuit must be protected with proper fuses See Table 1 on page 3 5 The mounting structure and the anchoring hardware must be capable of reliably supporting the weight of the heater and if used the mounting bracket ...

Page 2: ... You will need the following hardware for installation Enough 10 ga min insulated copper conductor with ground wire to run power from the breaker fuse to the heater Only use copper wire rated at least 60 C Do not use aluminum wire with this unit Proper size fuses or circuit breakers in accordance with the National Electrical Code Also see Table 1 page 3 Wood Screw 3 8 x 2 9 5 mm x 50 mm Lag bolts ...

Page 3: ...gned so they can not be complete ly closed Do not attempt to defeat this feature damage to the unit can result ADJUSTING HEAT OUTPUT Heat output can be increased or decreased by switching wires at the wattage change terminal board The heater is factory wired to deliver a heat output of 17 065 BTU per hour Should your particular application require less heat output refer to Table 1 and change the w...

Page 4: ...for all costs incurred in the removal or reinstallation of products including labor costs and shipping costs incurred to return products to Marley Engineered Products Service Center Within the limitations of this warranty inoperative units should be returned to the nearest Marley authorized service cen ter or the Marley Engineered Products Service Center and we will repair or replace at our option...