background image

Operation

1. Rotate the thermostat fully clockwise. This should 

energize the heating elements and cause warm air to 
flow from the hot air discharge at the openings in the bot-
tom of the grille.

2. After the operation check, rotate the thermostat to 

the desired position to obtain room comfort.
NOTE: For best results, the heater should be left “ON” 
constantly during the heating season because the ther-
mostat, when properly set, will maintain the desired     
temperature.

Cleaning & Maintenance

To maintain optimum performance and efficiency, heater should
be cleaned and checked periodically. It is recommended the
heater be cleaned at least annually. (more often if used in a
dirty environment)

To Clean Heater:

1. Disconnect power to heater at main panel or breaker.
2. Remove thermostat knob (if provided) and remove front
cover 

(grille) as follows: (See figure 4)

–Insert screw driver through bottom louver and loosen one 

screw that holds latch mechanism.

–Lift front cover upward and pull top outward to remove.

3. Push ON/OFF switch to OFF position.
4. Using vacuum cleaner knozzle, brush, or dust cloth, remove 

dust and any foreign material from heater. Use care to not 
bend fan blade or damage heater wiring. (Spin blade by

hand 

to make sure it turns freely.)

5. Push ON/OFF switch to ON position.
6. Replace front cover and secure latch mechanism. (See
instal-

lation of heater Assembly and Grille.)

7. Reconnect power to heater and verify that heater operates  

properly.

TO RESET MANUAL RESET LIMIT:

Your heater is equipped with a manual reset safety thermal limit
control that will automatically turn the heater off to prevent a fire
if the heater overheats. This control is located on the fan panel
assembly  between  the  element  and  fan  blade  and  marked
“reset”. The red reset button can be seen through the front grille
when  the  heater  is  installed. To  reset,  allow  the  heater  to  cool,
then push the red button that is visible through the hole in the fan
panel. The heater should immediately return to normal operation.

MODEL NO. 

FRC4024C

DATE CODE: 

0302

FAN FORCED WALL HEATER
APPAREIL DE CHAUFFAGE MURAL À AIR PULSÉ

VOLTS AC

60HZ          WATTS        PHASE

240

4000 1

MUST BE USED WITH FRABB BACK BOX.
DO NOT OPERATE WITHOUT FRCFC FRONT COVER IN PLACE.

DOIT ÉTRE UTILISÉ AVEC FRABB BOÎTIER ARRIÈRE NE PAS
UTILISER 
SI LE COUVERCLE AVANT FRA N EST PAS EN PLACE.

DEBE USARSE CON CAJA POSTERIOR FRBB
NO DEBE ENCENDERSE SIN LA CUBIERTA SERIE FRC-FC

MARLEY ENGINEERED PRODUCTS
BENNETTSVILLE, SC 29512  USA

774G LISTED

ROOM HEATER

NAMEPLATE

LIMITED WARRANTY

All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from date of installation,
except heating elements which are warranted against defects in workmanship and materials for five years from date of installation. This warranty does not
apply  to  damage  from  accident,  misuse,  or  alteration;  nor  where  the  connected  voltage  is  more  than  5%  above  the  nameplate  voltage;  nor  to  equipment
improperly installed or wired or maintained in violation of the product’s installation instructions. All claims for warranty work must be accompanied by proof of
the date of installation.

The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return 
products to Marley Engineered Products Service Center. Within the limitations of this warranty, inoperative units should be returned to the nearest Marley
authorized service center or the Marley Engineered Products Center, and we will repair or replace, at our option, at no charge to you with return freight paid
by Marley. It is agreed that such repair or replacement is the exclusive remedy available from Marley Engineered Products.

THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MER-
CHANTABILITY AND  FITNESS  FOR A PARTICULAR  PURPOSE  WHICH  EXCEED  THE AFORESAID  EXPRESSED  WARRANTIES ARE  HEREBY DIS-
CLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES
ARISING WITH RESPECT TO THE PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.

Some states do allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This war-
ranty gives you specific legal rights, and you may also have other rights which vary from state to state.

For the address of your nearest authorized service center, contact Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise returned 
to the factory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered Products. When request-
ing return authorization, include all catalog numbers shown on the products.

CAUTION

TO PREVENT POSSIBLE ELECTRIC SHOCK, ALWAYS DISCON-
NECT ALL POWER TO HEATER AT MAIN DISCONNECT PANEL
OR  FUSE  BOX  BEFORE  CLEANING  OR  MAINTENANCE  TO
HEATER.

!

HOW TO ORDER REPAIR PARTS

In order to obtain any needed repair or replacement

parts,  warranty  service  or  technical  information,  please
contact Marley Engineered Products Service Center toll-
free by calling  1-800-642-HEAT. 

When ordering repair parts, always give the informa-

tion listed as follows:

1. The Part Number 
2. The Model Number 
3. The Part Description
4. Date of Manufacture

03-02

Part No. 5200-2152-003   

4

ECR 35194

!

399761087

SPX Corporation
470 Beauty Spot Rd. East
Bennettsville, SC  29512 USA

Summary of Contents for FRC3027C

Page 1: ...ocedures and cut your installation time to a minimum TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK 1 Disconnect all power coming to heater at main service panel before wiring or servicing 2 All wiring must be in accordance with the National and Local Electrical Codes and the heater must be grounded 3 Verify the power supply voltage coming to heater matches the ratings printed on the heater nameplate be...

Page 2: ...nections 3 Mounting Back Box a Place the back box into wall opening flush with fin ished wall surface on bottom and sides of box Top flange of back box should protrude approximately 1 2 or 12 7mm from finished wall surface b Secure the back box in place with wood screws or nails 4 Wiring Disconnect Switch a Connect the power supply wires to the blue wires of the disconnect switch using wire connec...

Page 3: ... the box h Secure disconnect switch bracket in place Installation of Heater Assembly and Grille After back box is completely installed and no further con struction dirt is expected clean debris from back box remove heater assembly from its carton Refer to Figure 4 and pro ceed as follows 1 Insert the heater assembly into back box placing the four mounting holes with key hole slots over the screws ...

Page 4: ... installation except heating elements which are warranted against defects in workmanship and materials for five years from date of installation This warranty does not apply to damage from accident misuse or alteration nor where the connected voltage is more than 5 above the nameplate voltage nor to equipment improperly installed or wired or maintained in violation of the product s installation ins...

Reviews: