background image

      As carefully as possible, remove the solids basket using the 

black handles. Be sure to lift the basket vertically and with 

equal pressure.

Allow excess water to drain over the grease trap. If necessary, 

the basket can be stood on a flat surface but be aware that 

remaining water will continue to drain from the collected solids. 

Then move the solids basket to a waste receptacle/recycling 

point.

      To empty the captured solids, place a finger against the top 

of the filter screen to prevent it from sliding out then turn the 

solids basket on its side and tip the contents into the waste 

container. Now remove the filter screen and wipe clean both 

the solids basket and  filter screen with a paper towel, rinsing 

them as necessary to remove all accumulated debris. Warm 

water, detergent and a small stiff brush is recommended.

Refitting is the reverse of removal.

Note: Some very fine debris may pass through the solids 

basket and accumulate on the floor of the grease trap. This 

together with the fat and oils should be cleaned and removed, 

by an accredited waste removal company. 

3

www.marleypipesystems.co.za  |  011 739 8600

www.marleypipesystems.co.za  |  011 739 8600

2

General Installation Guidance

Piping Connections

Installation Options

The Marley Endura Grease Trap will require at least 45-50cm 

clearance above the tank to allow the solids basket to be 

removed for cleaning. The tank is marked with ‘IN’ and ‘OUT’ 

above the respective connections.

Connections to the tank are 

designed to receive 50mm or 

75mm SSN couplings. 

Dependent on the current 

plumbing installation.

45-50cm

SSN Coupler

All Marley Endura Gease Traps are manufactured with no 

hub connections. Standard mechanical joint (SSN) couplings 

can be used to connect the grease trap to a metal or plastic 

piping system. If the piping system needs to be resized, use 

appropriate mechanical joint reducers, but do not decrease 

pipe diameter across the unit.

Please Note: The Marley Endura Grease Trap is 

made of Polypropylene, which is not compatible 

with solvent weld cement.

Marley Endura Grease Trap

complete with Solids Basket 

(MG200, MGT500, MGT700)

The Marley Endura Grease Trap is a self-contained unit  

designed to work with grease trap applications with a flow rate 

of 1.6 to 3.2 litres per second.

Typical Installation

Minimum Solids Basket Clearance of 45-50cm

is required for cleaning access.

45-50cm

Solids Basket

Sink

Grease Trap

Semi Recessed Option

Fully Recessed Option

On Floor Option

Grease Trap Operation

Solid Basket Operation

Your purchase of the Marley Endura Grease Trap represents a 

sound investment in the effective operation of your foodservice 

establishment. 

Train your employees so they can contribute to your goal 

of responsible waste management and reduced mainte-

nance cost. 

Provide training in:

• proper function, operation and maintenance of grease  

  traps;

• proper storage, handling and disposal of wastes;

• proper separation and storage of materials;

• proper use and handling of cleaning aids;

• proper housekeeping; and

• the benefits of following the code and best practise 

The Solids Basket has one removable screen.

The screen has moulded details to ensure it is fitted in the 

correct location, and has flow direction arrows moulded onto 

the top surface.

The Solids Basket incorporates the outlet along the bottom 

downstream edge and recirculates the flow upward and 

alongside the basket. 

1

2

Directional Arrows for easy

screen placement

Solids Basket

Directional Arrows

Fine Screen

1

2

Maintenance & Removal

1

2

Installation

Marley Endura  Solids Basket 

(MGTSOL01)

Maintenance & Removal

1

Please note: When properly 

installed, there will be a gap of 

approximately 15cm between 

the bottom of the solids basket 

and the floor of the grease 

trap. This is the correct opera-

tional location for the device.

Approx. 15cm

Flow

Calculate Flow Rates

All grease traps must be cleaned regularly to maintain efficient 

operation. 

The frequency of grease and solids removal is dependent upon 

a variety of factors; the type of food served, the capacity of the 

grease trap and the quantity of grease in the water. Increasing 

the frequency of cleaning will reduce odour problems associ-

ated with grease traps and improve retention efficiency.

To empty the Solids Basket, lift all the latches on the grease trap  

cover into the upright position and open the grease trap.

Sink L x B x H = cm

2

cm

2

 ÷ 1000 = Litres

Litres x 0.75(Factor) = Volume

Volume ÷ 60(Seconds) = Litres per Second

Formula: (LxBxH) ÷ 1000 x 0.75 ÷ 60 = ℓ /sec

For flow rates lower than or equal to 1.6ℓ /sec, use a MGT500.

For flow rates greater than 1.6ℓ /sec and up to 3.2ℓ /sec use a 

MGT700.

7.6m max

2

Reviews: