Marlec HRDi Installation And Operation Manual Download Page 6

HRD

i

 Charge Regulator 

Installation and Operation

Easy Steps To Avoiding Damage / Ensuring Optimum Operation

1. 

During installation or maintenance set the “Stop” position. See 

Fig 1 

:-

2. 

Do not use the “Stop” switch as a brake to stop a Windcharger that is in

fast rotation.  If possible first orient the turbine to a downwind position to slow it down.

3. 

During installation the first “live” connection must be to the battery.
This configures the 12V or 24V operation.

4. 

Never disconnect the HRD

i

 from the battery unless the “Stop” switch is

activated and ensure reconnection is made before returning to the “Run”
position.  Any on-board  battery management systems must not break this
connection.

5. 

Never connect an open circuit running Windcharger to the HRD

as this

will cause permanent damage.

6. 

Never make the connection of a solar panel in direct sunlight to the HRD

.

7. 

Do not exceed the recommended 160W of solar panels. 

Note : in ambient temperatures >40°C

the solar panel input must be de-rated.  Contact your dealer or the manufacturer for advice.

8. 

Always fit an appropriate blocking diode to each solar panel input.

9. 

Never connect the HRD

i

 to the battery or any charge sources in reverse polarity.

10.  Avoid exceeding the recommended wiring distance between HRD

i

 and battery.  Longer distances

require heavier gauge cable or charging efficacy will be affected.

11.  Never obstruct the ventilation slots of the HRD

i

.

Please take note of these steps to avoid the loss of warranty cover.

Notes

In high levels of auxiliary charge, eg from an engine, the HRD

i

 may enter regulating mode and thus

the windcharger will run at a slow speed.

The logging feature of the HRD

i

 will continue to record up to 9999 Ah or 9999 hours duration

before automatically returning to zero. (if not reset by user in the meantime)

The memory in the HRD

 saves the latest settings made and these are retained even if the unit is

disconnected. Reconnection immediately re-activates these settings.

The reprogramming of the Max V/Cell @ 25° C ( see * ) may only be necessary when using non

lead-acid batteries and limited types of Gel batteries. See battery manufacturers advice. We strongly
advise against making any changes in this value as batteries may be permanently damaged.

STOP

CHARGE

Fig 1  Charge / Stop

Switch

Summary of Contents for HRDi

Page 1: ...HRDi Charge Regulator Installation and Operation RUTLAND HRDi CHARGE REGULATOR INSTALLATION AND OPERATION ...

Page 2: ... input must be de rated Contact your dealer or the manufacturer for advice May be connected in parallel with other charge sources not through the HRDi For use with a single or dual battery bank Clear alpha numeric digital LCD screen with user display options Push button activated and timer controlled backlight Accepts up to 6 mm2 cable SWG 11 or AWG 9 Optional remote display can be added to dedica...

Page 3: ...attery positions BAT1 BAT1 and if a second bank is used BAT2 BAT2 It is ESSENTIAL that BAT1 is connected as this link provides internal power for the HRDi Connect BAT2 before BAT1 if both are to be used 7 Connect the 2 Windcharger cables to the Windcharger positions WG WG and the solar panel cables to the solar panel positions PV PV ensuring correct polarity is observed Note Solar panels must be f...

Page 4: ...d Low will alternate Multistage Charge Mode Either with the voltage reading for values below 11 0 V 25 C Charging Mode Either Charge Current may be flowing into the battery bank s Charge Reg Regulation has begun but some current may still flow into battery bank s Reg No current is flowing to the battery bank s as the mode has shifted to Regulation and the Windcharger will run very slowly Bulk Bulk...

Page 5: ...ory Setting Default is YES Toggle to NO and press OK to save the changes made Or Press OK and factory settings are restored Note At any time in reprogramming procedure if no button is pressed for 30 seconds then normal operation is returned without any changes being saved It is not recommended that this value be changed for all lead acid batteries Temperature compensation adjusts charging level to...

Page 6: ...advice 8 Always fit an appropriate blocking diode to each solar panel input 9 Never connect the HRDi to the battery or any charge sources in reverse polarity 10 Avoid exceeding the recommended wiring distance between HRDi and battery Longer distances require heavier gauge cable or charging efficacy will be affected 11 Never obstruct the ventilation slots of the HRDi Please take note of these steps...

Page 7: ...me WG Windcharger HRDi Charge Regulator PV Solar Module Max 160 W BLOCKING DIODE MUST BE FITTED Battery 1 WG WG PV PV BAT BAT BAT2 BAT2 Cut Away of HRDi Wiring Block Wiring block Parallel panels each require a blocking diode Battery 2 In Line Fuse Supplied With Windcharger ...

Page 8: ...egulator Installation and Operation Sunshine Solar Limited Unit 30 Ashwellthorpe Industrial Estate Ashwellthorpe Norwich Norfolk NR16 1ER Tel 44 0 1508 488 188 Email sales sunshinesolar co uk www sunshinesolar co uk ...

Reviews: