![marklin BR 103 Manual Download Page 17](http://html.mh-extra.com/html/marklin-0/br-103/br-103_manual_1728276017.webp)
17
Betrieb • Operation • Fonctionnement
Exploitatie • Operación • Operazione
( )
Values = factory settings
DCC: programming on the programming track by means of CV programming,
programming with PoM (Program on the Main); this must be supported by the controller you are using.
*
The values for the desired setting must be added!
Example: The number of speed levels 28/128 = 2 + DCC operation with a braking route = 4, results in the value = 6
CV
Discription
6021 Value
DCC Value
60
PoM
Multiple station announcements
Bit 0 – 3 = Number of stations
Bit 4 = Last station reverses the sequence.
Bit 5 = Locomotive direction determines the sequence.
Bit 6 = Basic setting for sequence.
—
0 – 127 (42)
61
PoM Random sound: Interval min.
—
0 – 255 (30)
62
PoM Random sound: Interval max.
—
0 – 255 (50)
63
PoM Volume
01 - 63 (63)
0 – 255 (255)
66
PoM Reverse trim
—
0 – 255 (128)
95
PoM Forward trim
—
0 – 255 (128)