Markilux 790 Installation Notes Download Page 2

 
 
 

3.Installing / hanging up the awning  

3.1  Remove  the  protective  covering  and  check  all  parts 

are present.  

3.2  Mark  holder  site  where  it  is  to  be  attached  with  drill 

holes and then drill.  Both holders are to be installed 
with  a  20  cm  gap  to  the  outer  edges  of  the  cassette 
awning. 
Additional brackets may be used.  

3.3  Fasten  the  holders  vertically  above  one  another.  

They must be mutually aligned. (plumb line).  

3.4  Hang  the  cassette  in  the  holders,  position  it  and 

tighten the  SW10 securing screws.  

3.5  Mark  the  position  of  the  tension  sectioning  fastening 

means  depending  on  awning  extension  length  and 
fasten them in place.  

 
Retaining  post  with  base  plate    is  to  be  screwed  in 
horizontally sited on a strong base.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Retaining  post  with  ground  sleeve:  anchor  the  sleeve 
plumb  vertically  in  concrete,  push  the  sectioning  into  the 
sleeve  and  then  slide  the  retaining  post  on.  Clamp  the 
post in place with the hexagonal SW13 screw. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Wall holder: screw the wall plate approximately 985 mm 
high  on  the  wall  and  mount  the  wall  holder  using  the 
cylindrical SW4 screws.  
 
 
 
 
 
 
 
 
 
 
 
 
 
3.6  The  handle  position  can  be  adjusted  with  the 

clamping screw on the tensioning arm.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3.7  Set  its  height  so  that  the  awning  is  tensioned  dead 

straight.   

  Caution.  The  clamping  screws  must  be 

retightened after adjusting the handle height.  

 

3. Safety note 

 Caution.  Awning under tension. Keep a  good  hold 

of the handle when extending.  
 

4. Important  

Hand over the attached Operating Instructions to the 
awning user  and  advise  him  or  her  comprehensively 
on awning safety and use. 

Cap 
 
Retaining 
post  
 

Cap 
 
Retaining post  
 
Insertion sec-
tioning  
Cover 
 
Ground sleeve  

M5x30 cylindrical 
screws  
 
Cap 
 
Wall holder  
 
Wall plate 

Clamping screws  
 

Grooved 
arm   
 
Handle 

Summary of Contents for 790

Page 1: ...st with base plate 1 retaining post with ground sleeve or 1 wall holder 1 Fastening means Overview of dimensions Tension sectioning fastening means 2 Recommendations and instructions on fastening holders in place This side awning is supplied without assembly screws as differing wall materials etc require differing types of fastening Fastening means must be such as safely distribute the forces exer...

Page 2: ...e anchor the sleeve plumb vertically in concrete push the sectioning into the sleeve and then slide the retaining post on Clamp the post in place with the hexagonal SW13 screw Wall holder screw the wall plate approximately 985 mm high on the wall and mount the wall holder using the cylindrical SW4 screws 3 6 The handle position can be adjusted with the clamping screw on the tensioning arm 3 7 Set ...

Page 3: ...3 4 mobilfix 779311 optional 5 mobilfix 779311 optional ...

Page 4: ...l as the operating guides are to be read and observed The markilux operating guide as well as the setting instructions of the motor switch and controller manufacturers are to be handed over to the user with a written confirma tion and fitted wind class see handover declaration He is to be comprehensively enlightened about the safety and usage information of the awning With non observance and malop...

Page 5: ...conversions not intended by the manufacturer may only be performed with the written consent of the manufacturer Additional loading of the awning due to suspended objects or due to tensioned ropes cables can lead to damage or to the collapse of the awning and are therefore not permitted The awning may not be subjected to high temperatures strong vibrations or shaking or strong mechanical stress An ...