TS-E ELECTRIC COUNTERTOP STEAMERS

TROUBLESHOOTING

GENERAL TROUBLE-SHOOTING GUIDE

PROBLEM

PROBABLE CA

USE

REMEDY

COOKING INDICATOR LIGHT 

FAILS TO LIGHT WITH TIMER 

SET.

a.  Main power circuit breaker tripped.
b.  Door interlock switch contacts not 

closed.

c.  Door interlock switch faulty.
d.  Indicator light burned out.
e.  Faulty timer contacts.
f.  Faulty wiring.
g.  Fuse blown.

a.  Locate external circuit breaker for incom-

ing power and place in ON position.

b.  Shut cooker door to close switch contacts. 

Check alignment of door with switch.

c.  Replace switch.
d.  Replace light.
e.  Replace timer.
f.  Inspect condition of wire and tightness of 

all connections. Correct as needed.

g.  Replace with same rated fuse.

STEAM FAILS TO GENERATE 

WITH COOKING INDICATOR 

LIGHT ON.

a.  Faulty wiring.

a.  Inspect condition of wire and tightness of 

all connections. Correct as needed.

STEAMS CONTINUOUSLY
WITHOUT THE COOKING OR 

READY LIGHT ON.

a.  Faulty thermostatic switch.

a.  Replace thermostat.

TIMER DIAL NOT TURNING.

a.  Faulty timer motor.
b.  Faulty wiring.

a.  Replace timer.
b.  Inspect condition of wire and tightness of 

all connections. Correct as needed.

BUZZER FAILS TO SOUND AT 

END OF TIMER SETTING.

a.  Timer contacts faulty.
b.  Buzzer faulty.
c.  Faulty wiring.

a.  Replace timer.
b.  Replace buzzer.
c.  Inspect condition of wire and tightness of 

all connections. Correct as needed.

COMPONENT TESTING
Exterior Panel Removal

   WARNING

To prevent hazard in servicing the cooker, be 

certain that the electrical disconnect circuit 

breaker for the steamer is OFF before remov-

ing side panels.

Access to all internal plumbing and electrical assemblies 

is from the right side. The right-side panel is removed by 

removing the bottom screws from panel.

60-MINUTE TIMER
Timer Contacts

Defective timer contacts will result in failure of cooker 

compartment to operate. When this occurs, remove the 

side panel and proceed as follows:
1.  Turn off power at external circuit breaker.
2.  Disconnect all three wires from timer terminals.

3.  Connect an ohmmeter between terminals 21 and 22.
4.  Rotate timer dial beyond the “0 - Minute” point (any 

setting) to obtain a reading of zero ohms on the ohm-

meter. If zero ohm reading cannot be obtained, timer 

contacts are defective and the timer must be replaced.

5.  Move ohmmeter leads to terminals 21 and 24.
6.  Rotate timer dial to “0 - Minute” position. (An audible 

click indicates correct position). If zero ohm reading 

cannot be obtained, the timer is defective and must 

be replaced.

7.  Move ohmmeter leads to terminals 11 and 12.
8.  Rotate the timer dial to the “CONSTANT STEAM” po-

sition. If zero ohm reading cannot be obtained, the 

timer is defective and must be replaced.

9.  Remove ohmmeter and replace all three leads on 

timer terminals.

Summary of Contents for TS-3E

Page 1: ...ARKET FORGE Telephone 802 658 6600 Fax 802 860 3732 www marketforge com P N 14 0291 Rev C 6 17 Superseding All Previous Parts Lists The Company reserves the right to make substitution in the event that items specified are not available ERRORS Descriptive and or typographic errors are subject to correction ...

Page 2: ...JUNE 12 2017 2 TS E ELECTRIC COUNTERTOP STEAMERS TABLE OF CONTENTS TROUBLESHOOTING 3 ELEMENT BLOCK REPLACEMENT 5 WIRING DIAGRAMS 6 ILLUSTRATED PART LIST TS E EXPLODED VIEW 9 FLOOR DRAIN KIT ASSEMBLY 12 ...

Page 3: ...ace buzzer c Inspect condition of wire and tightness of all connections Correct as needed COMPONENT TESTING Exterior Panel Removal WARNING To prevent hazard in servicing the cooker be certain that the electrical disconnect circuit breaker for the steamer is OFF before remov ing side panels Access to all internal plumbing and electrical assemblies is from the right side The right side panel is remo...

Page 4: ...orrect position for that timer the timer set and the door latches closed If 240 volts is present the fault is in the indicator light and requires replacement If 240 volts is not present the fault is in the wiring or control components selector switch timer or door switch Buzzer If the buzzer does not sound at the termination of the operator selected timer setting timer dial returned to 0 Minute po...

Page 5: ...nd set aside 6 Remove two screws that retain the component mount ing board carefully supporting it and saving from damage Leave it rest at the side of the unit 7 Remove the unit base by removing four screws near the face of the unit and set aside Remove the insula tion to expose the element plate 8 Remove the failed element block and residual heat sink compound 9 Apply about 4 ounces of heat sink ...

Page 6: ...JUNE 12 2017 6 TS E ELECTRIC COUNTERTOP STEAMERS NFG WIRING DIAGRAMS 208 240V ...

Page 7: ...JUNE 12 2017 7 TS E ELECTRIC COUNTERTOP STEAMERS NFG WIRING DIAGRAMS 380 600V ...

Page 8: ...JUNE 12 2017 8 TS E ELECTRIC COUNTERTOP STEAMERS NFG WIRING DIAGRAMS 380 220 415 240V ...

Page 9: ...JUNE 12 2017 9 TS E ELECTRIC COUNTERTOP STEAMERS TS E EXPLODED VIEW ...

Page 10: ...LY 240V 415V 15 KW 1 97 6762 ELEMENT ASSEMBLY 480V 15 KW 1 97 6763 ELEMENT ASSEMBLY 600V 15 KW 1 7 97 6764 SPRING DISC 3 4 OUTSIDE DIAMETER 18 18 8 97 6765 HEX NUT 5 16 18 9 9 9 97 6766 COMPARTMENT DRIP PAN 1 1 10 97 6767 DECAL TS 3E 1 97 6768 DECAL TS 5E 1 11 97 6270 PILOT LAMP GREEN READY 1 1 12 97 6271 PILOT LAMP RED COOKING 1 1 13 08 3826 KNOB 1 1 14 97 6732 SWITCH ON OFF 1 1 15 97 6769 PILOT ...

Page 11: ...5052 GROUNDING LUG 1 1 39 97 6738 EARTH ID TAG 1 1 40 08 6502 PRESSURE SWITCH 1 1 41 97 6780 PRESSURE SWITCH BRACKET 1 1 42 97 6781 COMPONENT BOARD 1 1 43 97 6307 BUZZER 1 1 44 97 6280 REPLAY DPDT 2 2 45 97 6178 STRIKER 1 1 45A 97 6650 LOCK WASHER 1 1 45B 97 6302 STAINLESS STEEL WASHER 1 1 45C 97 6651 HEX NUT 1 2 20 UNF 1 1 46 97 6429 SWITCH ACTUATOR ROD WITH CLIP 1 1 47 97 6191 DOOR SWITCH 1 1 48...

Page 12: ...CONE HOSE 5 LONG 1 1 2 08 1206 HOSE CLAMP 1 1 3 90 8030 1 2 x 3 4 HOSE BARB 1 1 4 10 2863 1 2 90 STREET ELBOW BRASS 1 1 5 97 6211 LEG 4 4 These parts provide a means of draining the steam generator to a suitable drain or collector These ports will not complete the connection additional parts will be needed and may be obtained locally ...

Reviews: