TS-E ELECTRIC COUNTERTOP STEAMERS
TROUBLESHOOTING
GENERAL TROUBLE-SHOOTING GUIDE
PROBLEM
PROBABLE CA
USE
REMEDY
COOKING INDICATOR LIGHT
FAILS TO LIGHT WITH TIMER
SET.
a. Main power circuit breaker tripped.
b. Door interlock switch contacts not
closed.
c. Door interlock switch faulty.
d. Indicator light burned out.
e. Faulty timer contacts.
f. Faulty wiring.
g. Fuse blown.
a. Locate external circuit breaker for incom-
ing power and place in ON position.
b. Shut cooker door to close switch contacts.
Check alignment of door with switch.
c. Replace switch.
d. Replace light.
e. Replace timer.
f. Inspect condition of wire and tightness of
all connections. Correct as needed.
g. Replace with same rated fuse.
STEAM FAILS TO GENERATE
WITH COOKING INDICATOR
LIGHT ON.
a. Faulty wiring.
a. Inspect condition of wire and tightness of
all connections. Correct as needed.
STEAMS CONTINUOUSLY
WITHOUT THE COOKING OR
READY LIGHT ON.
a. Faulty thermostatic switch.
a. Replace thermostat.
TIMER DIAL NOT TURNING.
a. Faulty timer motor.
b. Faulty wiring.
a. Replace timer.
b. Inspect condition of wire and tightness of
all connections. Correct as needed.
BUZZER FAILS TO SOUND AT
END OF TIMER SETTING.
a. Timer contacts faulty.
b. Buzzer faulty.
c. Faulty wiring.
a. Replace timer.
b. Replace buzzer.
c. Inspect condition of wire and tightness of
all connections. Correct as needed.
COMPONENT TESTING
Exterior Panel Removal
WARNING
To prevent hazard in servicing the cooker, be
certain that the electrical disconnect circuit
breaker for the steamer is OFF before remov-
ing side panels.
Access to all internal plumbing and electrical assemblies
is from the right side. The right-side panel is removed by
removing the bottom screws from panel.
60-MINUTE TIMER
Timer Contacts
Defective timer contacts will result in failure of cooker
compartment to operate. When this occurs, remove the
side panel and proceed as follows:
1. Turn off power at external circuit breaker.
2. Disconnect all three wires from timer terminals.
3. Connect an ohmmeter between terminals 21 and 22.
4. Rotate timer dial beyond the “0 - Minute” point (any
setting) to obtain a reading of zero ohms on the ohm-
meter. If zero ohm reading cannot be obtained, timer
contacts are defective and the timer must be replaced.
5. Move ohmmeter leads to terminals 21 and 24.
6. Rotate timer dial to “0 - Minute” position. (An audible
click indicates correct position). If zero ohm reading
cannot be obtained, the timer is defective and must
be replaced.
7. Move ohmmeter leads to terminals 11 and 12.
8. Rotate the timer dial to the “CONSTANT STEAM” po-
sition. If zero ohm reading cannot be obtained, the
timer is defective and must be replaced.
9. Remove ohmmeter and replace all three leads on
timer terminals.
Summary of Contents for TS-3E
Page 6: ...JUNE 12 2017 6 TS E ELECTRIC COUNTERTOP STEAMERS NFG WIRING DIAGRAMS 208 240V ...
Page 7: ...JUNE 12 2017 7 TS E ELECTRIC COUNTERTOP STEAMERS NFG WIRING DIAGRAMS 380 600V ...
Page 8: ...JUNE 12 2017 8 TS E ELECTRIC COUNTERTOP STEAMERS NFG WIRING DIAGRAMS 380 220 415 240V ...
Page 9: ...JUNE 12 2017 9 TS E ELECTRIC COUNTERTOP STEAMERS TS E EXPLODED VIEW ...