INSTALLATION
2
SERVICE CONNECTIONS
Electrically Operated
EC
Electrical Connection- for incoming power supply wires
on terminal block.
EP
Power Supply- 1 3/4” (44mm) DIA. access holes for
power supply wires. Use wire suitable far at least 90
o
C.
Nominal amp per line wire per oven 10.4KW
Volts
1pH
3pH
208 (197-219)
50
30
230 (220-240)
44
25
480 (460-500)
--
12.5
Details of other electrical systems available upon request.
NOTES:
Allow 2” space from side wall and 2”
space from rear wall if adjoining wall is com
-
bustible.
All stands are 32” front to back. When used
with deep oven overhang may either front or
back as desired (recommended overhang is
in back). Allow 3 3/4” on front for door handles
and controls.