Using an RJ45 cable, connect the positive output from the 12VDC supply to either pin 4 
or 5 on either the side or rear RJ45 connector of the sign.  To illuminate the word 
"SECURE" connect either pin 1 or 2 on either RJ45 connector to the ground output of the 
power supply.  To illuminate the word "NONSECURE" connect either pin 3 or 6 on 
either RJ45 connector to the ground output of the power supply. 
 
As an example, to display the word "SECURE" when port C on the SecureSwitch is 
selected, and to display the word "NONSECURE" when port A is selected, make the 
following connections: 
 
Connect the GND lead of the power supply to one "A" status output and to one "C" status 
output on the SecureSwitch. 
Connect the other "A" status output on the SecureSwitch to pins 3/6 of the RJ45 
connector on the sign, and connect the other "C" output to pins 1/2 on the sign. 
Connect the +12 VDC lead on the power supply to pins 4/5 on the sign. 

 
NOTE: Either of the two unused screw terminals (pins 3 and 6) on the SecureSwitch 
status output connector can be used as a convenient place to make the wire 
connection between the positive lead from the power supply and the pin 4/5 leads for 
the RJ45 cable that connects to the sign. 

 
In the above example, when port A on the  SecureSwitch is selected, the A-A status 
output relay closes connecting ground of the power supply to pins 3/6 on the sign, 
causing the word "NONSECURE" to be displayed.  Likewise, the word "SECURE" is 
displayed when port C on the SecureSwitch is selected.  The sign will remain blank 
(OFF) when port B on the SecureSwitch is selected (see example wiring diagram on next 
page).  
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

    Example 1 Wiring Connections 

 
 
 

    

POWER 

    SUPPLY 

 
 GND   +12v 

Summary of Contents for 51-01198

Page 1: ...ember 2012 Wall Mount Part Number 51 01198 1U Rack Mount Part Number 51 01196 19 North Main Street Houston PA 15342 Phone 412 494 2800 Fax 412 494 5550 www secureswitch com CAGE Code 1BGJ7 Copyright 2012 Market Central Inc All rights Reserved ...

Page 2: ...als reduces the resistance of the interconnect cable allowing the sign to be located further from the SecureSwitch 2 Introduction The SECURE NONSECURE LED sign provides a means of displaying the security level of a video teleconference or similar session It is designed to connect directly to the status output dry contact closure interface on the revision B and revision C SecureSwitch products or i...

Page 3: ...he SecureSwitch to pins 3 6 of the RJ45 connector on the sign and connect the other C output to pins 1 2 on the sign Connect the 12 VDC lead on the power supply to pins 4 5 on the sign NOTE Either of the two unused screw terminals pins 3 and 6 on the SecureSwitch status output connector can be used as a convenient place to make the wire connection between the positive lead from the power supply an...

Page 4: ...RE when port A is selected and to display the word SECURE when the SecureSwitch has either port B or port C selected simply connect the two B contacts in parallel to the two C contacts as shown below Example 2 Wiring Connections RJ45 Jack pinout looking into opening POWER SUPPLY GND 12v ...

Page 5: ...arts Correction in the manner provided above shall constitute a complete fulfillment of all obligations and liabilities of Market Central with respect to the quality of said products THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OF QUALITY WHETHER WRITTEN ORAL OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PURPOSE THIS WARRANTY AND ...

Reviews: