background image

10

3.3.2 CLASSIC 

300 

TROUBLESHOOTING

Error: the amplifier doesn’t start-up Warning: the amplifier keeps functioning Message: operating messages

Display Message

Type

Explanation

Power supply failure!

Error

The power supply has failed. Contact an authorized technician for repair.

Amplifier failure!

Error

The power amplifier has failed. Contact an authorized technician for repair.

Cabinet not connected!

Error (until you connect a
cabinet)

No cabinet is connected to your amplifier.

Cabinet impedance/short!

Error (until you connect correctly
to a suitable cabinet)

The impedance of your cabinet/s is too low, or there is a short circuit. Check your
connection and/or your cabinet/s.

Temp too high!

Error (until the temperature
decreases)

The temperature inside the amplifier has reached an unsafe level.
Make sure the amplifier is properly ventilated.

V(#) tube failure!

Warning

One or more tubes are not working correctly or have failed.
You should have the tube/s replaced by an authorized technician as soon as possible.

Main voltage too low!

Warning

Main power supply voltage is below the nominal value by 10% or more.

Main voltage too high!

Warning

Main power supply voltage is above the nominal value by 10% or more.

Markbass
Classic 300

Message

Startup message

Amp Management System V#.#

Message

Software version. This message appears during startup.

Tube heating

Message

Duration: 32 seconds. This message appears during startup. A progress bar shows the
time remaining until the amp is ready to use.

Long Life – biasing..###

Message

Duration: approximately 10 seconds. This message appears during the power tube biasing
phase, when Long Life mode has been selected.

.

High Fidelity – biasing..###

Message

Duration: approximately 10 seconds. This message appears during the power tube biasing
phase, when High Fidelity mode has been selected.

Ready

Message

This message appears after the biasing phase, when the amplifier is working properly and
ready for use.

Standby

Message

You have selected standby mode. Press standby again when you’re ready to use the amp.

Mute

Message

You have selected mute mode. Use the footswitch to deactivate mute mode when you’re
ready to use the amp.

Summary of Contents for CLASSIC 300

Page 1: ...OWNER S MANUAL CLASSIC 300 v 22 june 2007...

Page 2: ...attractive design and extreme reliability all in one impossibly lightweight unit This amp will allow your instrument to speak in its natural voice faithfully conveying your musical ideas to your audi...

Page 3: ...so on I was able to accomplish this The Markbass amplifier circuitry is designed specifically not to color the sound of the bass but to faithfully reproduce the unique tonal qualities of whatever ins...

Page 4: ...e chaleur tel qu un radiateur un fourneau ou bien un autre appareil qui produit de la chaleur 9 Ne pas modifier le syst me de s curit de la fiche polaris e ou de de la fiche pour les prises de terre U...

Page 5: ...er clockwise Then turn your instrument s volume up to its full level and play as hard as you do in your most aggressive moments and turn up the GAIN 2 control until the red light starts illuminating N...

Page 6: ...nd dance LOW MIDs MID LOW or Mid Frequency Low make your bass sound loud projecting the sound over long distances filling the room HIGH MIDs MID HIGH or Mid Frequency High convey the pitch of the note...

Page 7: ...ontrol is set to a center frequency of 80 Hz This means that it either boosts or cuts the volume of the frequencies around 80 Hz to a maximum of 12 decibels The LOW MID MID LOW 5 EQ control boosts or...

Page 8: ...effects chain a battery dies or a cable gives out for example while you re playing you will not lose your main signal If desired however the effects loop can be easily modified by authorized service...

Page 9: ...ed by the microcontroller Every time the head is switched on the power tubes are accurately biased This creates the optimal conditions for sound quality every time you power up The advanced biasing pr...

Page 10: ...rized technician as soon as possible Main voltage too low Warning Main power supply voltage is below the nominal value by 10 or more Main voltage too high Warning Main power supply voltage is above th...

Page 11: ...r frequency 800 Hz level 12 dB HIGH center frequency 3 kHz level 12 dB OUTPUTS SEND EFFECTS unbalanced max voltage 18 Vpp TUNER OUT unbalanced max voltage 2 5 Vpp LINE OUT balanced XLR max voltage 25...

Page 12: ...5 CLASSIC 300 BLOCK DIAGRAM 20 dB EQUALIZER Pre Post Footswitch Mute Mute Return Send Line Out Tuner Jumper Series Parallel Jumper Parallel LIMITER Power Amp Power Output Input MICROPROCESSOR DISPLAY...

Page 13: ...3 6 CLASSIC 300 EQ GRAPHS 13...

Page 14: ...Italy 66020 San Giovanni Teatino Ch Via Aterno 44 Tel 39 085 446 5705 Fax 39 085 440 7399 www markbass it info markbass it Product speci cations are subject to change without notice...

Reviews: