6

The software version number will be displayed for a short time followed by "FLtA". The
following secondary functions of keys are used during the configuration process.

ADVANCE

Step through menu choices

ENTER

Select a menu choice

ESCAPE

Quit any function (no change)

 

&

 

Increment or decrement displayed values

The following list shows all configuration options. 

Italics

 indicate factory settings.

FLtA - Analog filter

FA 0

2.5 Hz RC filter disabled

FA 1

2.5 Hz RC filter enabled

FLTd - Digital filters

FC 1

No filtering of current (displayed) readings

FC 2

Average of 2 samples for each reading

FC 4

Average of 4 samples for each reading

FC 8

Average of 8 samples for each reading

FP 1

No filtering of peak readings

FP 2

Average of 2 samples for each peak reading

FP 4

Average of 4 samples for each peak reading

FP 8

Average of 8 samples for each peak reading

232 - RS-232 settings

232d

Output Disabled

232E

Output Enabled

300

300 baud

600

600 baud

1200

1200 baud

2400

2400 baud

4800

4800 baud

9600

9600  baud

7-1E

7 data bits, 1 stop bit, even parity

7-1o

7 data bits, 1 stop bit, odd parity

7-2E

7 data bits, 2 stop bits, even parity

7-2o

7 data bits, 2 stop bits, odd parity

7-2n

7 data bits, 2 stop bits, no parity

8-1E

8 data bits, 1 stop bit, even parity

8-1o

8 data bits, 1 stop bit, odd parity

8-1n

8  data bits, 1 stop bit, no parity

8-2n

8 data bits, 2 stop bits, no parity

Ft F

Full data (n units)

Ft n

Numeric data only

out - Outputs selection (other than RS-232)

SP d

Set point outputs disabled

SP E

Set point outputs enabled

Summary of Contents for BG012

Page 1: ...Series BG DIGITALFORCE GAUGES User s Guide...

Page 2: ...ECTION 4 6 EXTERNAL TRIGGER MODE SECTION 5 6 SET POINTS SECTION 6 7 AVERAGE MODE SECTION 7 7 GAUGE CONTROL LANGUAGE SECTION 8 8 OUTPUTS SECTION 9 10 RS 232 10 Mitutoyo BCD 10 Analog 10 I O connector p...

Page 3: ...dings DATA Initiates a data transmission sequence if equipped with the communication option MODE ADVANCE Switches the display between normal and peak modes of operation CLEAR ESCAPE Clears peak readin...

Page 4: ...a steady LO BAT indicating approximately one hour of charge remaining The second level is indicated by a flashing LO BAT At the third level the whole display except the LO BAT indicator will flash for...

Page 5: ...es for each reading FP 1 No filtering of peak readings FP 2 Average of 2 samples for each peak reading FP 4 Average of 4 samples for each peak reading FP 8 Average of 8 samples for each peak reading 2...

Page 6: ...itted 8 Every 8th sample transmitted 16 Every 16th sample transmitted 32 Every 32nd sample transmitted 64 Every 64th sample transmitted 128 Every 128th sample transmitted AoFF Automatic shutoff settin...

Page 7: ...or set to their minimum acceptable values for highest peak capture speed EXTERNAL TRIGGER MODE This mode of operation is useful for measuring electrical contact activation force as well as synchroniza...

Page 8: ...either case SP will appear on the display and the ENTER key may be used for re entering the set point change mode or the MODE key for proceeding with the normal operation of the gauge AVERAGE MODE Thi...

Page 9: ...Auto transmit every nth reading n 0 1 2 4 8 16 32 64 128 0 disabled LB Switch units to pounds KG Switch units to kilograms N Switch units to Newtons G Switch units grams ET Enable External trigger mo...

Page 10: ...ware version the last field shows the remaining battery power B0 full charge B3 minimum power All other fields show the status of settings and features using the same abbreviations as the commands to...

Page 11: ...ion to data collectors printers multiplexers or any other device capable of accepting Mitutoyo BCD data The transmission is initiated by the DATA key or by the receiving device see Section 3 for setti...

Page 12: ...ssing ESCAPE SPECIFICATIONS Section 11 General Accuracy 0 2 of full scale 1 count Tare capacity 110 of capacity Display shows at 110 Overload capacity 150 of capacity Display shows at 110 Sampling rat...

Page 13: ...nvironment or use other than intended will void this warranty This warranty is in lieu of all other warranties includ ing implied warranties of merchantability and fitness for an intended purpose In n...

Reviews: