Page .... 30
Maritime Geothermal Ltd.
17-Feb-00
NORDIC® EMDX-HW Series Electrical Box
208v/3/60 Box – Heating & Domestic Hot Water Versions
NOTE (A)
Electric Heat Back-up is
An option which can be
activated or deactivated by
the customer by discon-
necting the breaker as re-
quired. To disconnect per-
manently – remove wires
D, E & F at left.
E
F
D
Electric Heat
Breaker & Relay
A