Marine ComNav 20350001 Installation Instructions Manual Download Page 1

Marine Ltd. 

 

CT2-40A  

MOTOR CONTROLLER 

PART NUMBER 20350001 

DOCUMENT PART NUMBER 29010024 

ComNav

R

 

Permanent Magnet 

z

 Shunt Field Compound 

z

 D.C. Motors 

 

 

ComNav

Installation Instructions 

Version 3.3 

ComNav Marine Ltd.  #15-13511 Crestwood Place.  Richmond, B.C.  Canada.  V6V-2G1 

 

Telephone:  604-207-1600             Facsimile:  604-207-8008 
Web:  www.comnavmarine.com   E-mail:  [email protected]  

Document PN 29010024 

Summary of Contents for ComNav 20350001

Page 1: ...Nav R Permanent Magnet z Shunt Field Compound z D C Motors ComNav Installation Instructions Version 3 3 ComNav Marine Ltd 15 13511 Crestwood Place Richmond B C Canada V6V 2G1 Telephone 604 207 1600 Fa...

Page 2: ...2 2 5mm to 1 4 6 5mm For mounting a 10 size hole is provided in each foot of the 2T Motor Controller box The Autopilot and the CT2 Motor Controller must be run from the same source of power although t...

Page 3: ...ction movement place the Autopilot master select switch in the POWER STEER position and press either the red or green ARROW key The rudder should move in the correct direction If not reverse M1 and M2...

Page 4: ...If the motor doesn t run 1 If the motor is a Shunt Field or Compound Motor check that full within a volt battery voltage appears between J1 Field and J1 Field when there is 5V between J2 5V and Test...

Page 5: ...me noise is heard on the vessel radios and it is traced to the motor controller a ground lug has been provided to bond it to the vessel s grounding system In most cases this should eliminate any elect...

Page 6: ...TBD SW PWR SPD CNTL 5V COM MOTOR MON 1001 1101 1201 JOG PORT JOG STBD JOG COM 12 24 VDC JOG LEVER NOT SUPPLIED BATTERY 30A FUSE OR BREAKER 1 2 3 4 10 40 VDC MOTOR AUTOPILOT DISTRIBUTION BOX Figure 2 C...

Page 7: ...SW PWR SPD CNTL 5V COM MOTOR MON 1001 1101 1201 JOG PORT JOG STBD JOG COM JOG LEVER NOT SUPPLIED 1 2 3 4 10 40 VDC MOTOR SHUNT FIELD MOTOR AUTOPILOT DISTRIBUTION BOX FLD 30A FUSE OR BREAKER 12 24 VDC...

Page 8: ...D M1 M2 FLD SHUNT UNSW PWR PORT STBD SW PWR SPD CNTL 5V COM MOTOR MON 1001 1101 1201 JOG PORT JOG STBD JOG COM 12 24 VDC JOG LEVER NOT SUPPLIED BATTERY 30A FUSE OR BREAKER 1 2 3 4 10 40 VDC MOTOR COM...

Page 9: ...20A F1 FIELD FIELD U3 V BOOST O C F B 6 5 4 1 2 TO 5V M1 M2 3 4 5 6 TO PROCESSOR BOX TO MOTOR 5 TO BAT 12 24 32 VDC 5 TO CT2 BOX M2 M1 BLACK WHITE TO BAT 12 24 32 VDC PROCESSOR WHITE 3 GREEN BLACK 1 2...

Page 10: ...1 2 4 3 5 DI P SWI T CH ES UP DOWN 3 1 2 4 24 32 VDC 12 VDC 1 Make sure it is in UP position for solenoid setup 2 Keep in down position 3 Keep in down position If using analog output interface A1100...

Page 11: ...Keep in down position 3 Set as per voltage application shown above Switch should be set to 12 for 12 VDC application or set to 24 for 24 VDC application Make sure power is turned off to the pilot sys...