Troubleshooting
Symptom
Cause
Solution
Device cannot be switched on.
Display is blank and no other
reactions is observed.
Excessive battery discharge.
Start charging battery for at least 30
minutes before attempt to switch on
the device. After few minutes, the
red led the will start blinking.
Broken device (flooded, charged
from improper source), does not
react when charging
Factory service needed.
Device is switching on and off
continuously.
One of the internal sensors may be
damaged.
Connect the charger for 1 minute. If
this will not help, allow the device to
discharge its battery and to switch
off. Wait 1 hour, and try to charge it
again. If this will not help, return the
device for service.
When switched on, the device shows
“Battery is low!” message and
switches off.
The battery is discharged too much.
Charge the device.
The charging process never ends.
Broken battery.
Return the device for service.
Damaged charging cable or dirt/rust
on its connector.
Clean the charger connector. Make
sure it is not cut or damaged.
Charging source too weak.
Try another charger. You may use
the USB port of a laptop/PC.
The depth indication is 0 and never
changes.
Depth shown is invalid.
Defective pressure sensor.
Go to Settings / Pressure/salin. If the
pressure is near 0, the sensor is
defective and factory service is
needed.