background image

22

Maintenance of the Juvaura

TM

 Device

Cleaning the Juvaura

TM

 Device 

Clean your Juvaura

TM

 after each treatment, and 

never 

clean 

the Juvaura

TM

 device or any of its parts with water or any other 

fluid.

 DANGER!  RISK OF ELECTRIC SHOCK

  Always 

unplug

 the Adaptor from the wall before cleaning.   

  Turn the Applicator off by pressing the On/Off Switch.

  Allow cooling down of its Treatment Surface.

  Wipe the Treatment Surface with a dry cloth or paper towel - 

make sure not to allow any moisture to penetrate the seams of 
the unit, do not get it wet.

Summary of Contents for Juvaura

Page 1: ...USER MANUAL...

Page 2: ......

Page 3: ...as historically only been available at dermatologist and plastic surgeon offices or exclusive spas including ours The Juvaura LED Anti Aging Device puts the sophisticated science behind infra red ligh...

Page 4: ...s of using the JuvauraTM Device How To Use the JuvauraTM Device JuvauraTM Setup JuvauraTM Battery Charging What to do before each treatment Plan your JuvauraTM treatment for best results Directions fo...

Page 5: ...5 Read this User Manual before using the JuvauraTM LED infrared device for the first time Before You Start...

Page 6: ...d device JuvauraTM is an LED infrared device which emits energy in the red and ir region of the spectrum The device is used for the treatment of various signs of aging including fine lines resulting i...

Page 7: ...lines and wrinkles During Treatment Red infrared light penetrates deep down to the hypodermis stimulating the production of collagen After Light Therapy Skin surface is revived with high density of c...

Page 8: ...el Bag A H D K B I E L C J F M G N Treatment Surface Green Light Working Indicator Applicator Plug Indicator LEDs Green Light Reminder Indicator Green Light Finished Charging Adapter ON OFF switch Bas...

Page 9: ...nce at the same time When the Working indicator light H shines steady green the applicator is ready for use Please note if the Working indicator light H continues blinking the device needs to be charg...

Page 10: ...al outlet Treatment Surface Light is delivered to the skin through the Treatment Surface when it is in contact with the skin The Treatment Surface is made of stainless steel The inner cycle has nine L...

Page 11: ...otherapy treatments Discontinue use if you encounter any discomfort or skin redness that lasts for more than two days You may have sensitivity to light or another condition Consult with your doctor WA...

Page 12: ...the JuvauraTM device only for its intended use and as described in its manual PRECAUTIONS TAKE THE FOLLOWING PRECAUTIONS TO AVOID MINOR OR MODERATE INJURY AND DAMAGE TO YOUR DEVICE Do not use if you...

Page 13: ...The JuvauraTM Applicator has a built in safety feature for eye protection It has been designed so that light can not be emitted when the Applicator is facing open air The safety switch is activated o...

Page 14: ...he JuvauraTM device This should disappear within 24 48 hours after treatment Store the device in a clean area free of dust JuvauraTM cannot tolerate extreme change of temperature When moved from a col...

Page 15: ...of fine lines and wrinkles Best results can be expected 3 4 weeks after completing the recommended course of treatment JuvauraTM Setup Remove the JuvauraTM Base Unit Applicator and other components f...

Page 16: ...our JuvauraTM is in the process of charging When Battery Charging Indicator Light F turns off and the Battery Full Indicator Light E illuminates your JuvauraTM is fully charged and ready to start The...

Page 17: ...the first month 4 weeks treatment should be performed 3 times a week for 15 20 minutes each time 3 5 minutes on each treatment zone JuvauraTM treatment regimen After the first month use the JuvauraTM...

Page 18: ...e has an inactivity timer that will automatically shut off the device if it is not in contact with the skin after 1 minute WARNING THE DEVICE IS NOT FOR USE ON EYELIDS OR OPEN EYES Helpful Tip Make su...

Page 19: ...the Base Unit Press the On Off Switch The green Working Indicator Light H will start blinking and shortly afterwards will shine steady Your JuvauraTM is ready for treatment If the Error Indicator Ligh...

Page 20: ...ply a small amount of a moisturizing cream on the treated skin areas after each session and massage it gently in circular motions Step 6 Clean your device after every use and return to charging cradle...

Page 21: ...on Some Mild Red Color After each JuvauraTM session you may notice a slight reddening of the skin mild erythema over the treated area This is normal and should fade within 24 48 hours Discontinue use...

Page 22: ...ts with water or any other fluid DANGER RISK OF ELECTRIC SHOCK Always unplug the Adaptor from the wall before cleaning Turn the Applicator off by pressing the On Off Switch Allow cooling down of its T...

Page 23: ...Do not place or store the JuvauraTM LED infrared device where it can fall or be pushed into a tub sink or any other vessel containing water Keep the power supply cord away from heated surface Make su...

Page 24: ...Customer Service Possible Cause Solution The rechargeable batteries are empty Recharge the JuvauraTM device for 6 hours The Applicator is broken Contact Customer Service Possible Cause Solution The re...

Page 25: ...eck if the electrical outlet is working If the Applicator still does not charge contact Customer Service The Applicator is broken Contact Customer Service Possible Cause Solution This is normal No act...

Page 26: ...nction of the Applicator Press the On Off Switch twice to switch the Applicator off and on again If Yellow Error Indicator Light G comes on again contact Customer Service Possible Cause Solution Malfu...

Page 27: ...or its official distributor will repair or replace it Warranty will not cover normal wear and tear of the device Warranty will not cover misuse or mistreatment of the device If you did not purchase t...

Page 28: ...ication No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Marilyn Monroe Spas Dat...

Page 29: ...d heating therapy Wavelength 700 5nm 850 5nm 940 5nm Therapeutic temperature range 41 2 C 105 8 35 6 F Storage condition Temperature 10 C to 60 C 14 F to 140 F Relative humidity 5 95 Operating conditi...

Page 30: ...tery 7 4Vd c 900mAh Product Size 20 x 4 6 x 7 9cm Distributed By 7700 Municipal Drive Orlando FL 32819 Degree of protection against electric shock Type BF applied part Follow the instructions for use...

Page 31: ...31 Specification...

Page 32: ...Marilyn Monroe Rights of Publicity and Persona Rights The Estate of Marilyn Monroe LLC Photo Bernard of Hollywood 2018 Renaissance Road Inc marilynmonroe com...