Connect the power cable at the lower right side of the unit to the terminal block.
Each wire in the cable is labeled to correspond with spaces in the terminal block.
Make sure that you plug the appropriately labeled wire into the corresponding
space on the terminal block. Note that the unit will be connected to two circuit
breakers (Fig. 12).
Important Notes About Electrical Connections:
1.
Before beginning any work on the electric installation, be sure that the main
breaker panel switch is OFF to avoid any danger of electric shock. All mounting and
plumbing must be completed before proceeding with the electrical installation.
2.
All electrical work must comply with national and applicable state and local
electrical codes.
3.
All units must be connected to a properly grounded dedicated branch circuit of
proper voltage rating.
4.
This product requires three independent circuit breakers. Use threeinsulated
wires for the three separate double-pole breakers.
5.
When connecting the wires to the terminal blocks, make sure the metal wire ends
and the terminal blocks completely touch. Then, tighten the screws securely.
Failure to properly tighten can result in current escape and burning of the terminal
blocks.
14
Fig. 12
Reattach the cable for the LCD panel if disconnected and reinstall the front cover
using the screws and washers previously removed. (Fig. 13).
Connect the cold water supply to the threaded pipe labeled “inlet” and the hot water
to the threaded pipe labeled “outlet.” IMPORTANT: RUBBER WASHER MUST BE
USED FOR PROPER SEAL. (Fig. 14) Connections are 3/4” NPT.
15
Fig. 14
Fig. 13
Summary of Contents for ECO240
Page 1: ......