background image

 

 

 

®

®

 

 

 

 

 

Revision 1.2 

 

Page i 

 
 
 
 

 

WSO100 

Ultrasonic Wind / Weather Station  

 

User’s Manual 

 
 
 

Revision 1.2 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Copyright © 2012 Maretron, LLP All Rights Reserved 

 

Maretron, LLP 

9014 N. 23

rd

 Ave #10 

Phoenix, AZ 85021-7850 

http://www.maretron.com 

 
 

Maretron Manual Part #: M000901 

Summary of Contents for WSO100

Page 1: ...WSO100 Ultrasonic Wind Weather Station User s Manual Revision 1 2 Copyright 2012 Maretron LLP All Rights Reserved Maretron LLP 9014 N 23rd Ave 10 Phoenix AZ 85021 7850 http www maretron com Maretron...

Page 2: ...ocking compound and cleaning agents containing acetone Updated specification tables Added more information on configuration options and transmitted messages Corrected typographical errors Updated perf...

Page 3: ...bration 5 2 5 3 Wind Data Damping Period 5 2 5 4 Barometric Pressure Offset Calibration 5 2 5 5 Outside Humidity Offset Calibration 5 2 5 6 Outside Temperature Offset Calibration 5 2 5 7 Advanced Conf...

Page 4: ...WSO100 User s Manual Page iv Revision 1 2 This page intentionally left blank...

Page 5: ...Maretron WSO100 has the following features NMEA 2000 Interface Ultrasonic Wind Sensor Relative Humidity Sensor Barometric Pressure Sensor Temperature Sensor Waterproof Enclosure and Cable System 2 In...

Page 6: ...EA 2000 cable through the standard marine pole mount and the pole mount base and connect it to the WSO100 unit see Section 2 4 below Finally attach the WSO100 to the pole mount base using the included...

Page 7: ...ole mount base so that this hole will face forward Mounting Screw Lock Washer NMEA 2000 Cable Standard Marine Pole Mount Pole Mount Base Sensor Figure 1 Mounting the WSO100 to a Standard Marine Pole M...

Page 8: ...by connecting the female end of the cable to the WSO100 note the key on the male connector and keyway on the female connector Be sure the cable is connected securely and that the collar on the cable c...

Page 9: ...SO100 is not aligned exactly with the boat s centerline 2 5 3 Wind Data Damping Period You may adjust the damping that the WSO100 applies to transmitted wind speed and direction readings The WSO100 co...

Page 10: ...rogram the NMEA 2000 device instance for the temperature transmitted in PGN 130312 You usually will not need to modify the default value of 0 unless you have multiple temperature sensors on the networ...

Page 11: ...the Maretron DSM200 or other NMEA 2000 chartplotters or instrumentation displays with WSO100 configuration capability Please refer to your chartplotter display manual for details Users with direct ac...

Page 12: ...ration of the Maretron WSO100 follow the troubleshooting procedures in this section to remedy simple problems Symptom Troubleshooting Procedure No data output Check the connections to the NMEA 2000 co...

Page 13: ...Equipment Systems IEC 61162 3 Maritime Navigation and Radiocommunication Equipment Systems IEC 60945 FCC and CE Mark Electromagnetic Compatibility NMEA 2000 Parameter Group Numbers PGNs See Appendix A...

Page 14: ...ive Humidity 93 RH 40 per IEC60945 8 2 Vibration 2 13 2Hz 1mm 13 2 100Hz 7m s2 per IEC 60945 8 7 Rain and Spray 12 5mm Nozzle 100liters min from 3m for 30min per IEC 60945 8 8 Solar Radiation Ultravio...

Page 15: ...RETRON BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL...

Page 16: ...WSO100 User s Manual Page 12 Revision 1 2 This Page Intentionally Left Blank...

Page 17: ...WSO100 uses this PGN to provide a regular transmission of outside temperature relative humidity and atmospheric pressure The factory default for periodic transmission rate is twice per second The tra...

Page 18: ...smit identical SIDs for 130306 Wind Data and 130311 Environmental Parameters to indicate that the readings are linked together i e the data from each PGN was taken at the same time although they are r...

Page 19: ...field to a value of 0x00 to indicate that the temperature reading is a reading of atmospheric pressure 4 Pressure This field is used to indicate the atmospheric pressure in units of 0 1Pa 5 Set Humidi...

Reviews: