6  Troubleshooting 

If  you  notice  unexpected  operation  of  the  Maretron  VDR100,  follow  the  troubleshooting 
procedures in this section to remedy simple problems. 
 

Symptom 

Troubleshooting Procedure 

USB indicator 
not lit 

1.  Ensure that the USB flash drive is properly plugged into the USB 

connector 

NMEA 2000

®

 

indicator not lit 

1.  Ensure that power is supplied to the NMEA 2000

®

 indicator via the 

NMEA 2000

®

 cable, and that the NMEA 2000

®

 connection is secure. 

LAN indicator 
not lit 

1.  Ensure that the network cable is connected both to the VDR100 and 

to a switch or router or another network device. 

2.  Ensure  that  the  device  on  the  other  end  of  the  network  cable  is 

powered. 

VDR100 reports 
an “Error” state 

1. Ensure that the USB flash drive is properly plugged into the USB 

connector 

2. Try using a different USB flash drive 
3. Cycle the power to the VDR100 

VDR100 reports 
a “No Flash 
Drive” state 

1. Ensure that the USB flash drive is properly plugged into the USB 

connector 

2. Try using a different USB flash drive 

VDR100 reports 
a “Incompatible 
Flash Drive” 
state 

1. The VDR100 will not record on a USB flash drive which contains 

VDR100 upgrade software. If this USB flash drive is on the supported 
list in Section 4.2.1

, “USB Flash Drives”, simply use a Windows 

computer to erase the “VDR100_RCV” directory from the USB flash 
drive and reinstall the USB flash drive into the VDR100. 

N2KExtractor

®

 

Clients cannot 
successfully 
connect to the 
VDR100 

1.  If you have programmed the VDR100 to use DHCP, ensure that there 

is an active DHCP server on your LAN. 

2.  Ensure that the NMEA 2000

®

 connection is secure, and that the NMEA 

2000

®

 network is powered. 

3.  Ensure that you have entered the correct Serial Number or IP Address 

of the VDR100 into 

N2KExtractor

®

4.  Ensure that the LAN LED on the VDR100 is lit, indicating an active link 

connection to the LAN. If it is not lit, check the Ethernet connection 
and make sure that the router or device to which the VDR100 is 
connected is powered on. 

5.  Ensure that the Password entered into 

N2KExtractor

®

 under the 

“Connections Settings” window matches the password that has been 
programmed into the VDR100. 

Figure 3 

– Troubleshooting Guide 

 
If these steps do not solve your problem, please contact Maretron Technical Support (refer to 
Section 8 for contact information). 
 

Summary of Contents for VDR100

Page 1: ...2 Page i VDR100 Vessel Data Recorder User s Manual Revision 1 2 Copyright 2013 Maretron LLP All Rights Reserved Maretron LLP 9014 N 23rd Ave 10 Phoenix AZ 85021 http www maretron com Maretron Manual P...

Page 2: ...on 1 2 Revision History Revision Description 1 0 Original document 1 1 Added information on USB flash drive shipped with product 1 2 Firmware Release 3 0 2 9 Added information on LAN connections Added...

Page 3: ...VDR100 8 3 1 Advanced Configuration 9 3 1 1 Device Instance 9 3 1 2 Installation Description 9 3 1 3 Restore Factory Defaults 9 3 2 Label 9 3 3 Password 9 3 4 Configuring DHCP 9 3 5 Configuring IP Add...

Page 4: ...R100 User s Manual Page iv Revision 1 2 Table of Figures Figure 1 Mounting the VDR100 7 Figure 2 NMEA 2000 Connector Face Views 8 Figure 3 Troubleshooting Guide 14 Figure 4 Mounting Surface Template 1...

Page 5: ...Local Area Network port for accessing data remotely The Maretron VDR100 is designed to operate within the harsh demands of the marine environment However no piece of marine electronic equipment can f...

Page 6: ...ring the VDR100 Section 3 1 6 Theory of Operation The VDR100 records every frame of NMEA 2000 network activity onto the attached USB flash drive 1 6 1 General Concepts 1 6 1 1 Data Recording The VDR10...

Page 7: ...the USB flash drive is not compatible with Microsoft Windows Drivers for the filesystem used by the VDR100 are included with the Maretron N2KExtractor software 1 6 2 Operating States The VDR100 has s...

Page 8: ...00 should be at a known address 1 6 3 1 NAT Network Address Translation If you wish to use N2KExtractor to view data from a VDR100 on a WAN through an Internet connection please read this section If y...

Page 9: ...equest your ISP will assign you a Dynamic IP Address which may actually change from time to time In this way the ISP only needs to have enough addresses to cover its customers who are connected to the...

Page 10: ...or User s Manual for details WARNING Do not plug a USB flash drive that has been used in a VDR100 into a Windows PC without first installing the Maretron N2KExtractor software Failure to install the N...

Page 11: ...ection The NMEA 2000 network interface is already waterproof 2 The orientation is not important so the VDR100 can be mounted on a horizontal deck vertical bulkhead or upside down if desired 3 The VDR1...

Page 12: ...wer to the network is connected or disconnected Please follow recommended practices for installing NMEA 2000 network products Figure 2 NMEA 2000 Connector Face Views 2 4 2 LAN Connection The VDR100 ha...

Page 13: ...programmed with the same password in the Connections Settings Password field in the N2KExtractor software The default password is blank 3 4 Configuring DHCP This parameter determines whether or not th...

Page 14: ...to configure this parameter If the DHCP parameter is set to No you will need to configure this parameter 3 8 Configuring Default DNS This is the IP address of a computer on the Internet that can ident...

Page 15: ...32 64 Patriot Supersonic Boost XT 8 16 32 64 Patriot Supersonic Magnum 64 128 Sandisk Extreme USB 3 0 16 32 64 Sony Micro Vault Mach 8 16 32 64 SuperTalent SuperCrypt 16 32 64 128 256 SuperTalent Expr...

Page 16: ...will indicate the operating state of the VDR100 Please refer to Section 1 6 2 Operating States for details of the different states Solid ON Recording 1 Flash Formatting 2 Flashes Erasing 3 Flashes No...

Page 17: ...products N2KExtractor php Please refer to the N2KExtractor User s Manual available on the same web page for details 5 Maintenance Regular maintenance is not required however an occasional inspection w...

Page 18: ...s a Incompatible Flash Drive state 1 The VDR100 will not record on a USB flash drive which contains VDR100 upgrade software If this USB flash drive is on the supported list in Section 4 2 1 USB Flash...

Page 19: ...magnetic Compatibility NMEA 2000 Parameter Group Numbers PGNs Description PGN PGN Name Default Rate Response to Requested PGNs 126464 PGN List Transmit and Receive N A 126996 Product Information N A 1...

Page 20: ...n 2 13 2Hz 1mm 13 2 100Hz 7m s 2 per IEC 60945 8 7 Rain and Spray 12 5mm Nozzle 100liters min from 3m for 30min per IEC 60945 8 8 Solar Radiation Ultraviolet B A Visible and Infrared per IEC 60945 8 1...

Page 21: ...port for Maretron products you can reach us in any of the following ways Telephone 1 866 550 9100 Fax 1 602 861 1777 E mail support maretron com World Wide Web http www maretron com Mail Maretron LLP...

Page 22: ...allation Template Please check the dimensions before using the following diagram as a template for drilling the mounting holes because the printing process may have distorted the dimensions Figure 4 M...

Page 23: ...ETRON BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL M...

Reviews: