Maretron SMS100 User Manual Download Page 12

 

SMS100 User's Manual  

 

 

 

 

 

Page 8  

 

Revision 1.0 

Certifications 

Parameter 

Comment 

NMEA 2000

®

 Standard 

Level A 

Maritime Navigation and Radiocommunication Equipment & Systems 

IEC 61162-3 

Maritime Navigation and Radiocommunication Equipment & Systems 

IEC 60945 

FCC and R&TTE/CE Mark 

Electromagnetic Compatibility 

PTCRB Certified 
AT&T  

Network Ready 

 
NMEA 2000

®

 Parameter Group Numbers (PGNs)  

Description 

PGN # 

PGN Name 

Default Rate 

Response to Requested 
PGNs 

126464  PGN List (Transmit and Receive) 

N/A 

126996 Product 

Information 

N/A 

126998 Configuration 

Information 

N/A 

Protocol PGNs 

059392  ISO Acknowledge 

N/A 

059904 ISO 

Request 

N/A 

060416  ISO Transport Protocol, Connection Management 

N/A 

060160  ISO Transport Protocol, Data Transfer 

N/A 

060928 ISO 

Address 

Claim 

N/A 

065240 ISO 

Address 

Command 

N/A 

126208 NMEA 

Request/Command/Acknowledge 

N/A 

Periodic PGNs 

130834  SMS Status (Maretron Proprietary) 

10 seconds 

130835  SMS Text Message (Maretron Proprietary) 

On Receipt 

 

Electrical 

Parameter 

Value 

Comment 

Operating Voltage 

9 to 32 Volts 

DC Voltage 

Power Consumption 

<150mA 

Average Current Drain 

Load Equivalence Number (LEN) 

NMEA 2000

®

 Spec. (1LEN = 50 mA) 

Reverse Battery Protection 

Yes 

Indefinitely 

Load Dump Protection 

Yes 

Energy Rated per SAE J1113 

 

Mechanical 

Parameter 

Value 

Comment 

Size 

6.871” x 3.571” x 2.045” 

(152mm x 91mm x 52 mm) 

Including Flanges for Mounting 
Not Including Cellular Antenna 

Weight 

10.6 oz. (301 g)  

 

 

Environmental 

Parameter 

Value 

IEC 60945 Classification 

Exposed 

Degree of Protection 

IP65 

Operating Temperature 

-25°C to 55°C 

Storage Temperature 

-40°C to 85°C 

Relative Humidity 

93%RH @40° per IEC60945-8.2 

Vibration 

2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s

2

 per IEC 60945-8.7 

Rain and Spray 

12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8 

Solar Radiation 

Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 

Corrosion (Salt Mist) 

4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 

Electromagnetic Immunity 

Conducted, Radiated, Fast Transient, Supply, and ESD

 

per IEC 60945-10 

Safety Precautions 

Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12 

 
 

 

Summary of Contents for SMS100

Page 1: ...1 0 Page i SMS100 SMS Text Module User s Manual Revision 1 0 Copyright 2013 Maretron LLP All Rights Reserved Maretron LLP 9014 N 23rd Ave 10 Phoenix AZ 85021 http www maretron com Maretron Manual Part...

Page 2: ...SMS100 User s Manual Page ii Revision 1 0 Revision History Revision Description 1 0 Initial Release...

Page 3: ...SMS100 4 2 5 Connecting the SMS100 4 2 5 1 NMEA 2000 Connection 4 2 5 2 Cellular Antenna Connection 5 3 Configuring the SMS100 5 3 1 Advanced Configuration 5 3 1 1 Device Instance 5 3 1 2 Installatio...

Page 4: ...SMS100 User s Manual Page iv Revision 1 0 Table of Figures Figure 1 Mounting the SMS100 4 Figure 2 NMEA 2000 Connector Face Views 5 Figure 3 Troubleshooting Guide 7 Figure 4 Mounting Template 10...

Page 5: ...mobile phone to the SMS100 which will reply with basic ship s status The SMS100 has an NMEA 2000 port for communication with the attached NMEA 2000 network and an SMA antenna connector for connecting...

Page 6: ...100 2 Installation 2 1 Unpacking the Box When unpacking the box containing the Maretron SMS100 you should find the following items 1 SMS100 SMS Text Module 1 Parts Bag containing 4 Stainless Steel Mou...

Page 7: ...IM card must be installed into the SMS100 To install the SIM card please perform the following steps 1 Remove the four screws from the bottom of the SMS100 enclosure 2 Separate the top and bottom of t...

Page 8: ...ts then tighten the mounting screws until snug Figure 1 Mounting the SMS100 2 5 Connecting the SMS100 2 5 1 NMEA 2000 Connection The NMEA 2000 connector can be found on the side of the enclosure The N...

Page 9: ...y configure the SMS100 using a Maretron DSM150 or DSM250 display or Maretron N2KAnalyzer software 3 1 Advanced Configuration 3 1 1 Device Instance Program this parameter to the desired instance number...

Page 10: ...arious parameters on the vessel Send a SMS message containing the single word STATUS to the telephone number of the SMS100 The SMS100 will respond with a text message containing the following informat...

Page 11: ...y Cellular Provider signal strength and active SIM card status Check that the proper cellular telephone number has been programmed into N2KView the DSM150 or DSM250 No Cellular Provider Indicated Chec...

Page 12: ...n Receipt Electrical Parameter Value Comment Operating Voltage 9 to 32 Volts DC Voltage Power Consumption 150mA Average Current Drain Load Equivalence Number LEN 3 NMEA 2000 Spec 1LEN 50 mA Reverse Ba...

Page 13: ...pt any interference received including interference that may cause undesired operation CONTAINS FCC ID XPYLISAU200 9 Technical Support If you require technical support for Maretron products you can re...

Page 14: ...check the dimensions before using the following diagram as a template for drilling the mounting holes because the printing process may have distorted the dimensions Page 10 Revision 1 0 Figure 4 Moun...

Page 15: ...ETRON BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL M...

Reviews: