background image

 

 

 

 

Revision 1.0 

 

Page 15 

5  Troubleshooting 

If  you  notice  unexpected  operation  of  the  Maretron  MBB300C,  follow  the  troubleshooting 
procedures in this section to remedy simple problems. 

 

Symptom 

Troubleshooting Procedure 

No activity on the display 

Check the connection to the power and network 
connectors and tighten if necessary 
Ensure that power is supplied to the connected 
power cable. 
Check the connection to the power jack located on 
the rear of the device. 
Press the power switch located on the front of the 
device on the right-hand side. 
Check that the NMEA 2000

®

 interfaces are correctly 

connected to the NMEA 2000

®

 network. 

Other Issues 

Please refer to the Troubleshooting section of the 

N2KView

®

 

User’s Manual

 
If these steps do not solve your problem, please contact Maretron Technical Support (refer to Section 
Technical Support for contact information). 
 

Warning:  There  are  no  user-serviceable  components  inside  the  Maretron  MBB300C.  Opening  the 
MBB300C will expose the sensitive electronic components to adverse environmental conditions that 
may render the unit inoperative. Please do not open the MBB300C, as this will automatically void the 
warranty. If service is required, please return the unit to an authorized Maretron service location. 

 

Summary of Contents for MBB300C

Page 1: ...00C Vessel Monitoring and Control Black Box User s Manual Revision 1 0 Copyright 2016 Maretron LLP All Rights Reserved Maretron LLP 9014 N 23rd Ave 10 Phoenix AZ 85021 7850 http www maretron com Maret...

Page 2: ...MBB300C User s Manual Page ii Revision 1 0 Revision History Rev Description 1 0 Original document...

Page 3: ...4 Connecting the MBB300C 5 2 4 1 RS 232 Connection 6 2 4 2 Video Connection 7 2 4 3 LAN Connection 7 2 4 4 USB Device Connection 8 2 4 5 Power Connection 9 2 4 6 Power Sequencing 9 2 5 Configuring th...

Page 4: ...5 Figure 3 MBB300C Front Panel Connections 5 Figure 4 MBB300C Front Panel 6 Figure 5 LAN Connection 8 Figure 6 USB Device Connection 8 Figure 7 MBB300C Power Terminal Block 9 Figure 8 MBB300C Startup...

Page 5: ...B300C runs only N2KView software making it extremely stable and dedicated to monitoring and controlling your vessel The MBB300C is ruggedized for marine use and includes a solid state disk drive to wi...

Page 6: ...ts and new features are added The Maretron MBB300C is designed to operate within the harsh demands of the marine environment However no piece of marine electronic equipment can function properly unles...

Page 7: ...ay involves the following four steps Please refer to the individual sections for additional details Unpacking the Box Section 2 1 Choosing a Mounting Location Section 2 2 Mounting the MBB300C Section...

Page 8: ...ase contact Maretron 2 2 Choosing a Mounting Location The MBB300C must be mounted in an indoor location 2 3 Mounting the MBB300C The MBB300C can be mounted to a wall or other flat surface 2 3 1 Mounti...

Page 9: ...e panel located on the front of the MBB300C has the following I O interface connectors 2 x CAN bus ports with isolation for connection to NMEA 2000 2 x SATA HDD LED indicators 1 x Power Button with Po...

Page 10: ...There is one external RS 232 connector The RS 232 connector enables connection to an external touch screen To connect a serial cable with the RS 232 connector please follow the instructions below Ste...

Page 11: ...2 2 HDMI Connection There is one external HDMI connector The HDMI connector enables connection to a monitor To connect a HDMI cable with the HDMI connector please follow the instructions below Step 1...

Page 12: ...two external USB 2 0 connectors and two external USB 3 0 connectors To connect a USB device please follow the instructions below Step 1 The locations of the USB connectors are shown in Figure 3 and Fi...

Page 13: ...ive terminal to the center terminal Figure 7 MBB300C Power Terminal Block 2 4 6 Power Sequencing When the MBB300C is connected to an appropriate power source you can use the power switch located on th...

Page 14: ...hoose Exit in which case the MBB300C will power off 2 5 1 Manually Entering LAN Connection Information NOTE The LAN Connection is not necessary unless you are using any of the following features Video...

Page 15: ...9 above b Click on the Commands Settings tab on the right to display the Commands Settings Dialog Figure 10 Commands and Settings Dialog c Click on the Configuration button in the Commands Settings wi...

Page 16: ...gs window to display the Configuration dialog h In the Subnet Mask field enter the subnet mask value used on your LAN in most cases this value will be 255 255 255 0 i In the Default Gateway field ente...

Page 17: ...ve tab of the N2KView software Alternatively you can power down the unit by pressing the MBB300C s power switch Lastly you can power down the unit by turning off the power source with an external brea...

Page 18: ...ay remove paint or markings or may corrode the MBB300C enclosure or seals Do not use any cleaners containing acetone as they will deteriorate the plastic enclosure Do not spray cleaning liquids direct...

Page 19: ...he right hand side Check that the NMEA 2000 interfaces are correctly connected to the NMEA 2000 network Other Issues Please refer to the Troubleshooting section of the N2KView User s Manual If these s...

Page 20: ...nt FCC class A and CE Mark Electromagnetic Compatibility NMEA 2000 Electrical Parameter Value Comment Operating Voltage Dedicated Supply Connection 9 36 Volts DC Voltage Power Consumption Dedicated Su...

Page 21: ...port for Maretron products you can reach us in any of the following ways Telephone 1 866 550 9100 Fax 1 602 861 1777 E mail support maretron com World Wide Web http www maretron com Mail Maretron LLP...

Reviews: