2.  INSTALLATION 

a.  Mounting 

  Cut a Ø32mm circular cut out in the sink/counter for the font. 

  The  font  is  then  securely  mounted  as  shown  below  using  the  washer  and  nut 

provided.  

  The  wire  and  water  outlet  tube  should  pass  freely  through  the  large  hole 

through to the underside of the counter. 

  For added stability a bead of silicone sealant can be applied to the underside of 

the font around the perimeter. 

 

 
 

                                 

 

 
 

 

 
 

3.

 

Tighten the wing nut up 

while threading the wiring 
and tube through the 
mounting plate. 

1.

 Mount the font on 

the sink. Placing the 
threaded bar, hose 
and wiring through 
the hole. 

2

. Place the mounting 

plate back through the 
threaded bar, hose and 
wiring. Screw the wing nut 
back on with the washer. 

Summary of Contents for TUBULAR FONT

Page 1: ...Estate Dublin 18 Marco Beverage Systems Limited Shire House Strixton Manor Strixton Wellingborough Northants NN29 7PA Ireland Tel 353 0 1 295 2674 Ireland Fax 353 0 1 295 3715 Email sales marco ie ww...

Page 2: ...00584 02 02 15 Page 2 of 11 TABLE OF CONTENTS 1 INTRODUCTION 3 2 INSTALLATION 4 a Mounting 4 b Plumbing 5 c Electrical 6 3 CLEANING 7 4 RISK OF SCALDING 8 5 ASSEMBLY DRAWINGS 9 a Parts List 9 b Replac...

Page 3: ...installation This manual is not a substitute for any safety instructions or technical data affixed to the machine or its packaging All information in this manual is current at the time of publication...

Page 4: ...hrough the large hole through to the underside of the counter For added stability a bead of silicone sealant can be applied to the underside of the font around the perimeter 3 Tighten the wing nut up...

Page 5: ...should be securely fitted to the reducer connector on the font and the other end should be connected to the font water outlet connector A on the top of the boiler This tube should be trimmed to ensure...

Page 6: ...similar Mini Fit connector mounted on the top lid of the under counter boiler Note when connected to a Marco under counter boiler the electrical connections are not polarity sensitive If a non Marco F...

Page 7: ...Service Manual 1000584 02 02 15 Page 7 of 11 3 CLEANING The exterio of accidentally operating the font when cleaning around the font button...

Page 8: ...Page 8 of 11 4 RISK OF SCALDING Beware of The utmos in conditions that can cause bodily injury or damage to property If in doubt about the serviceability of the font always contact the manufacturer o...

Page 9: ...8 Tubular Font 2mm Ring 1401712 9 M3x10mm countersunk screw 1900393 10 Label round PtoD Caution Hot Water 1501221 11 Push button 2 pin 22mm 2200237 12 Tubular Font Clamping Plate 1401124 13 Tubular F...

Page 10: ...Service Manual 1000584 02 02 15 Page 10 of 11...

Page 11: ...Service Manual 1000584 02 02 15 Page 11 of 11 b Replacing the Button See below...

Reviews: