![Marco MIX 1000870 Instruction Manual Download Page 20](http://html1.mh-extra.com/html/marco/mix-1000870/mix-1000870_instruction-manual_1726506020.webp)
Troubleshooting
The screen of the boiler indicates various errors or problems with the machine. See diag-
nostic table below for futher details.
www.marcobeveragesystems.com
NSF/ANSI 4
E337347
Code / Icon
Type
Description
Action
Status
Boiler Ready
Status
Boiler not ready
Wait until the boiler ready symbol appears
Button
Description
Turn machine ON/ OFF (only in Tap
mode)
Press Button
Status
Dispensing (not in Tap mode)
Warning
Low water pressure
Check mains pressure
Warning
Descale flag
Check level probe for scale build up. Des-
cale the tank. Reset the Descale flag
F
Warning
Change filter flag
Change the filter. Reset the Filter flag
Check low level
probe!
Error
Probes connection mixed up / low level
probe failure
Call a qualified service technician
Check thermistor!
Error
Temperature sensor is out of range
Call a qualified service technician
Heater failure!
Error
Heating element not heating
Call a qualified service technician
Tank overfill!
Error
Too much water in the tank
Call a qualified service technician
Summary of Contents for MIX 1000870
Page 1: ...1 Instruction Manual Machine P N 1000870 1000871 1000880...
Page 6: ...6 Installation 1 2 3 4...
Page 16: ...16 Changing Filter 1 2 3 4...
Page 17: ...17 Cleaning Maintenance 1 2 3 4...
Page 18: ...18 Descale Proceedure 1 2 3 4 ALLOW MACHINE TO COOL COMPLETELY...
Page 19: ...19 Descale Proceedure 4 5 7 8 Repeat descale proceedure as required...