COUNTER CUT-OUT WITH DRIP TRAY

FRIIA C

 

5000860 

FRIIA C Tall 

5000863

FRIIA C Hands-Free 

5000857

FRIIA CS

 

5000862 

FRIIA CS Tall 

5000865

VENTILATION REQUIREMENTS

FRONT VENTILATION: 

Ventilation grilles cut out of standard cabinet door.

SIDE VENTILATION:

 Ventilation grilles cut out of standard 600mm 

cabinet. Grilles may be fitted on either side as long as they ventilate 
into an open unobstructed area.

BASE VENTILATION:

 Ventilation grilles cut in base panel and base 

plinth, a grille must also be cut out at the top of the cabinet.
•  At least 2 x vents 260mm/10.2” w x 65mm/2.5 h
•  The cabinet may be ventilated in many ways provided there are cut 

outs placed near the base and another near the top of the cabinet 
to take advantage of natural circulation.

UNPACKING INSTRUCTIONS

•  The chiller must be handled only in a vertical position. Transporting 

the appliance in a horizontal position can cause severe damage to 
the refrigerator.

•  Remove the exterior and interior packing. Packing materials 

(especially any plastic bags) should be stored out of the reach 
of children, as a potential source of danger. When disposing 
packaging parts, please follow current regulations on the matter, 
separating carton from plastic parts.

•  Always check that the equipment that is delivered corresponds to 

the model indicated in the accompanying document.

•  The equipment is shipped in a cardboard box. Once the packaging 

has been removed, check the equipment has not been damaged in 
transit; if damage is found, notify the carrier.

ELECTRICAL INSTALLATION PROCEDURE

When installing the machine, always observe the local regulations and 
standards. The appliance is supplied with a moulded power cord. A 
suitable mains power supply socket should be available within easy 
access of the appliance so that it can be disconnected easily after install. 
The standard machines are supplied with a UK 3-pin plug. For 
EU models a 2-pin CEE-7 plug will be supplied. US models will be 
supplied with the suitable plug. A suitable mains power supply socket 
should be available within easy access of the appliance so that it 
can be disconnected easily after install. The wires from the font are 
terminated in a Mini Fit connector which will plug into a similar Mini Fit 
connector mounted on the top lid of the undercounter boiler.

PLUMBING INSTALLATION PROCEDURE

•  Ensure that the equipment is installed according to local plumbing  

& water regulations.

•  Fit a stop valve on a cold water line and attach a 3/4” BSP male 

fitting, (eg. 3/4” x 1/2” 311 or washing machine type stop valve).

Suitable fittings are supplied with the kit to attach to the 3/4” BSP 

fitting to connect the supplied 3/8” hose.

•  Connect water supply lines following the installation drawings,  

as per installation guide (starting page 14).

•  In case filter systems are used verify that they satisfy the 

requirements of the legislation in force.

•  If the filter is new, turn on water and flush at least 10 litres  

(2.5 gallon) through the filter before to connect it to the cooler;  

if the filter is a used one, connect water inlet to the chiller.

•  To ensure that the maximum value of pressure of 3 Bar is not 

exceeded the chiller integrates a pressure reducer.

•  Turn on the water to flush any impurities, dust etc from the inlet hose and 

water pipe. Allow several litres through. Especially for new installations.

OPERATING THE CHILLER/CARBONATOR FOR THE 

FIRST TIME

•  Before connecting the appliance to the power source, let it stand upright 

for approximately 2 hours. This will reduce the possibility of a malfunction.

•  Check that all installation procedures have been carried out.
•  Ensure water inlet is open.
•  Before supplying power to the unit check water and Carbon Dioxide 

lines do not leak.

•  Plug the chiller into a suitable socket switch ON/OFF switch on the rear 

of the chiller to ON position. The “Power ON Status” light will light-up.

•  When the unit is on, the carbonation pump starts to fill. The 

carbonation device stops when it reaches the maximum level.

•  Once water and CO2 are connected, open the vent on top of the 

Chiller by pulling the ring. This operation allows the escape of any air 

bubbles present inside, which would affect the carbonation adversely.

•  On the pressure reducer knob, adjust CO2 pressure to a value 

between 50 and 65 PSI (350 and 450 kPa) (3.5 - 4.5 bar). This value 

depends on the temperature of the water and on the ambient 

temperature. The temperatures correspond to the CO2 pressure.

•  To enable filling the lines, open the two lines in the following order: 

cold sparkling water and cold natural water, until the flows appear 

regular and without the presence of air, in each case deliver and 

discharge at least 5 litres of water from each line.

•  At this point you can dispense water.

 369 

 437 

 600 

 600 

 100 min. 

 275 

 200 

Applies to model(s) 1000850# & 1000851# (where # is blank, or one or more alphanumeric characters)

DRAWN BY

DWG NO.:

PANEL REMOVAL

DESCRIPTION:

PJT 20-08-14

187

C.O.

FRIIA Assembly (in cabinet)

 31.5”/

800mm

  

 11.2”/

287mm

 

17.9”/

455mm

 10.2”/

259mm

 

 13.5

”/

345mm

 

 

4”

/

100mm

For drip-tray only

 

1.25”/

32mm

 3.25”

/82.5mm

 6.6”

/168mm

Cold / Sparkling

Power

1401482

1400820

Cold/Sparkling

Water

2301251

Summary of Contents for FRIIA C

Page 1: ...plete bundle FRIIA C Hands free 5000857 PACKAGING ITEM PACKAGING DIMENSIONS L x W x H mm WEIGHT Fonts all 290 x 570 x 215 1 65kg Chiller 500 x 320 x 520 31kg FRIIA components font and chiller are packed and shipped in individual boxes PLEASE NOTE PRODUCT INFO SIZE PERFORMANCE SPECS PLUMBING ELECTRICAL AND TECHNICAL SPECS NAME ORDER CODE DIMENSIONS D X W X H mm L HR CUPS HR POWER 220v PLUMBING REQS...

Page 2: ...0mm 11 8 300mm 10 2 260mm 2 5 65mm 1 9 50mm 2 5 65mm 10 4 265mm 10 4 265mm 1 9 50mm 2 5 65mm It is essential to allow for two ventilation points when installing FRIIA Vents are not supplied Where possible we recommend removing the back of your cabinet PLEASE NOTE CABINET Min 800mm h x 600mm w x 600mm d with 100mm clearance around machines all sides OPERATING ENVIRONMENT Cannot exceed temperature o...

Page 3: ...on flow rate of 1 4L min and ambient temperature of 20 25 C Chart indicates FRIIA chilling capacity based on incoming water temperature and desired output water temperate INCOMING TEMPERATURE C OUTPUT VOLUME L H Wipe down font daily with non abrasive cleaner Sanitise the system every 6 months after a filter change or after a period of inactivity more than 72 hours HOWTO CLEAN FRIIA We recommend us...

Page 4: ...plumbing water regulations Fit a stop valve on a cold water line and attach a 3 4 BSP male fitting eg 3 4 x 1 2 311 or washing machine type stop valve Suitable fittings are supplied with the kit to attach to the 3 4 BSP fitting to connect the supplied 3 8 hose Connect water supply lines following the installation drawings as per installation guide starting page 14 In case filter systems are used v...