Modes of Operations [ Service setup setting 5 ]:
Modes of OPERATION
- This boiler can operate in 3 different modes.
HEAT FILL – Standard operation the boiler will take in water until the
temperature in the tank dr ops, the inlet will close and the heating element is
activated. When the temperature reaches the set temperature the inlet will
reopen to take in more water. This cycle will continue until the Tank is Full.
This mode is used to ensure that the water temperature is controlled within set
values.
CONTINUOUS MODE – In this mode the boiler will take in water and activate
the element until the tank is full and the temperature has reached the set
temperature. Typically used in high demand situations where the temperature
stability is not primary concern.
COOL Mode – In this mode the temperature can be adjusted up or down
[function 1.] while in operation. Depending on the water level in the tank
selecting a lower temperature will cause either a message to “DISPENSE
WATER TO COOL THE TANK” or will automatically take in cooler water to
reduce the temperature to the new set temperature. In applications where
selecting different temperatures frequently is required this Cool Mode is best
selected.
Note in the Cool Mode this boiler will operate as a 5 ltr and not as a 10 ltr unit.
MANUAL FILL – if the boiler is not plumbed into a water supply the operator
must select Manual Fill mode for best operation of the boiler. In this mode the
water is added manually by the operator.
ECO Mode Operation:
N o t e
I n t he C O O L FI L L m o d e [ s e e S e r vi c e s et u p s e tt i n g 5 ] t h e E C O M o d e i s
a u to m a ti c a l l y s e l e c te d .
•
All ECO Boilers use high grade insulation and it is applied to give a significant energy usage
improvement over a standard water boiler.
•
The 10L ECO Boiler variants also incoprate a ½ tank ‘ECO mode’ function.
•
To enable the ‘ECO Mode’ press the button located below the ‘Ready’ indicator so that the leaf
symbol illuminates green.
•
This mode saves energy by mimimising the energy wasted during machine down-time.
•
NOTE: The ECO mode is most effective in installations where the machine has a regular ‘off’
period.
•
To achieve the most benefit from the energy saving ‘ECO Mode’ on your ECO boiler unit (10L
variants only), the following method should be employed:
o
Towards the end of the boilers operating period for a given day, switch the machine to
ECO Mode. Whilst maintaing water at 96
o
C, the machine tank will slowly drop to half
full, where it will remain.
o
At the end of the machines operating period it should the be turned ‘off’.
o
During the ‘off’ period as there is less water in the tank there will be less energy lost to
the surrounding environment resulting in an energy saving.
•
To disable simply press the ‘ECO Mode’ button again so that the leaf symbol is not illuminated