Marco 166 030 1C Instructions For Use Manual Download Page 3

©                    S.p.A.

TRANSPORTATION AND HANDLING

INSTALLATION

                PRELIMINARY CHECKS

                                       POSITIONING 

AMBIENT CONDITIONS

TEMPERATURE:

RELATIVE HUMIDITY:

min.-10°C 14°F-max.60°C 140°F

max. 90 %

OPERATING CYCLE

The pump  has  been designed  for discontinuous use. Under conditions  of high operating 

pressures (eg. with closed or blocked outlet, excessive length of the delivery circuit and/or 

excessive  pressure  due  to  accessories),  it  can  be  subjected  to  elevated  stresses  and 

overheating and therefore should not be used for prolonged periods under such conditions.

Due to limited weight  and dimensions the  pump does not require the use of  any  special 

handling  or  lifting  equipment. When  handling  manually,  normal  personal  protective  gear 

should be worn (safety shoes with toe piece, etc.). The pump is carefully packed prior to 

shipment. Upon receiving, the packaging should be inspected for damages and the pump 

stored in a dry area.

It is recommended that the use of the pump be according to normative safety standards 

and also as per the precautions listed below.

The pump can be mounted in any position. Fix the pump utilizing suitable diameter 

screws corresponding to the holes.

Check that there has been no damage to the pump during transportation or storage. Both 
inlet  and  outlet  ports  should  be  carefully  cleaned  removing  possible  dust  or  residual 
packaging  material.  Verify  that  the  available  electrical  power  supply  corresponds  to  the 
specification requirements.

WARNING:

 the above indicated temperature ranges are applicable to all components 

of the pump and these limits must be respected in order to avoid any possible damage 

or malfunctioning.

ENG

8

Summary of Contents for 166 030 1C

Page 1: ...S p A AVVERTENZE D USO INSTRUCTIONS FOR USE ELETTROPOMPA AUTOADESCANTE PER TRAVASO LIQUIDI SELF PRIMING ELECTRIC PUMP FOR TRANSFERRING VARIOUS LIQUIDS 166 030 1C VP45 AC 220V 01 04 14 Rev 01...

Page 2: ...ling of tractors and earth moving equipment transfer of water transfer of light weight lube oils antifreeze etc Tab 1 EN CODE TYPE VOLT l min 35 bar 1 kg 4 7 mm 0 75 gpm 9 2 psi 14 5 lb 10 4 AWG 18 WI...

Page 3: ...be worn safety shoes with toe piece etc The pump is carefully packed prior to shipment Upon receiving the packaging should be inspected for damages and the pump stored in a dry area It is recommended...

Page 4: ...avoid any pump contact with water splashes possibly causing water seepage into the motor with high risk of internal oxidationand or short circuit It is the responsibility of the installation technicia...

Page 5: ...n fresh water through it and to then loosen the front plate screws Upon re use run the pump briefly a few seconds and tighten the screws again Check under conditions of maximum operating pressure that...

Page 6: ...and and disposed of in an enviromentally correct manner The user is invited to effect a proper waste separation in order to facilitate the recycling of the materials of which the packing is composed 1...

Page 7: ...1 RONDELLA WASHER 4 1 CUSCINETTO BALL BEARING 5 1 MOTORE MOTOR 6 1 FLANGIA FLANGE 7 1 GIUNTO COUPLING 8 1 GRANO HEADLESS SCREW 9 1 ALBERO SHAFT 10 1 LINGUETTA KEY 11 4 VITE M5x16 SCREW M5x16 12 2 VIT...

Page 8: ...S p A SMONTAGGIO PORTAGOMMA TUBE OUTLET REMOVING ENG I T 13...

Page 9: ...S p A COLLEGAMENTO TUBING CONNECTIONS PORTATA MAX MAX FLOW RATE TIPO TYPE 1 3 2 4 ENG I T 14...

Page 10: ...S p A INGOMBRI DIMENSIONS mm pollici inches 91 5 3 5 8 74 5 2 7 8 166 6 1 2 120 4 3 4 187 7 3 8 25 1 71 2 3 4 90 3 1 2 6 1 4 276 10 7 8 113 4 1 2 ENG I T 15...

Page 11: ...A DIAGRAMMI DIAGRAMS DIAGRAMMA PORTATA FLOW RATE DIAGRAM DIAGRAMMA ASSORBIMENTO AMPERE DRAW DIAGRAM 0 10 20 30 40 0 0 2 0 4 0 6 0 8 1 1 2 bar l min 0 0 25 0 5 0 75 0 0 2 0 4 0 6 0 8 1 1 2 bar A ENG I...

Page 12: ...i delle pompe elettriche con liquidi che non superano la temperatura di 35 C Security of electric machines for the domestic use and similar uses Particular applications of electric pumps with liquids...

Page 13: ...S p A NOTE NOTES ENG I T 18...

Page 14: ...S p A Pagina intenzionalmente lasciata vuota Intentionally left blank ENG I T 19...

Page 15: ...stro sito internet www marco it Marco S p A Via Mameli 10 25014 Castenedolo Brescia Italia tel 39 030 2134 1 Fax 39 030 2134 300 Property of MARCO S p A reproduction prohibited All rights reserved For...

Reviews: