background image

©                    S.p.A.

AVVERTENZE D’USO

 

INSTRUCTIONS FOR USE 

ELETTROPOMPA AUTOADESCANTE 

PER TRAVASO LIQUIDI

SELF-PRIMING ELECTRIC PUMP 

FOR TRANSFERRING VARIOUS LIQUIDS

164 660 15 - UP2/E  12/24V

10/09/18 Rev

.02

Click

to

3D

Summary of Contents for 164 660 15

Page 1: ...p A AVVERTENZE D USO INSTRUCTIONS FOR USE ELETTROPOMPA AUTOADESCANTE PER TRAVASO LIQUIDI SELF PRIMING ELECTRIC PUMP FOR TRANSFERRING VARIOUS LIQUIDS 164 660 15 UP2 E 12 24V 10 09 18 Rev 02 Click to 3...

Page 2: ......

Page 3: ...e l adescamento E preferibile utilizzare almeno un primo tratto di tubazione flessibile in mandata della lunghezza minimadi 1 m When starting the pump or when emptying the tank slightly open the small...

Page 4: ...per pi di 5 volte consecutive il sistema si spegne in automatico per proteggere il motore e gli ingranaggi dal funzionamentoa secco Il LED multicoloresegnala Con led giallo fisso che la pompa non alla...

Page 5: ...pompa o premendo il pulsante di reset sul pannello di controllo sepresente Led giallo e led blu lampeggianti contemporaneamente indicano che la tensione di alimentazione fuori dai valori accettati Co...

Page 6: ...amper I campi di applicazione della pompa sono molteplici ma esclusivamente per i liquidi ammessi Tab 1 IT CODICE TIPO VOLT l min 10 bar 2 m 1 5 kg 1 3 mm 0 75 gpm 2 6 psi 29 0 ft 4 9 lb 2 9 AWG 18 FU...

Page 7: ...d immagazzinare in luogo asciutto Si raccomanda l uso secondo le disposizioni vigenti in termini di sicurezza e le precauzioni di seguitoriportate Controllare che la pompa non abbia subito danni duran...

Page 8: ...re la pompa ad una altezza eccessiva rispetto al livello minimo possibile del fluido da trasportare Se si supera l altezza massima la pompa pu non adescarerovinandosi Evitare strozzature del tubo sia...

Page 9: ...sto caso consigliabile prima dell avviamento introdurre direttamente del liquido nel corpopompa Ingresso di aria dal tubo di aspirazione a causa di possibile presenza di tagli mancanza di opportuna fa...

Page 10: ...coltarifiutiindicatedal governoo dalle autorit governativelocali SMALTIMENTO IMBALLO Si invita l utente ad effettuare un adeguata raccolta differenziata in modo da favorire il riciclo dei materiali di...

Page 11: ...than five times from priming to no liquid blue led off the circuit turns everythingoff anyway to protect themotor andthegearsfrom running without liquid ThemulticoloredLED signals With solid yellow LE...

Page 12: ...gyou have to reboot the circuit or presstheReset buttononthecontrol panel if present Yellow and blue LED that blink together indicate that the power supply is providing the wrong voltage Please check...

Page 13: ...of applications for the pump however only exclusively with the allowed liquids mentioned Tab 1 EN CODE TYPE VOLT l min 10 bar 2 m 1 5 kg 1 3 mm 0 75 gpm 2 6 psi 29 0 ft 4 9 lb 2 9 AWG 18 WIRE SIZE IP...

Page 14: ...to shipment Upon receiving the packaging should be inspected for damages and the pump stored in a dry area It is recommended that the use of the pump be according to normative safety standards and al...

Page 15: ...avoidany possibleenvironmental dispersion In this case frequent cleaning and maintenance of the filter is advisable The standardfilter withstands a maximumpositive pressure of0 5 bar The electrical in...

Page 16: ...he pumphas run dry for too long a period Long periods of inactivity In this case it is advisable to add liquid directly into the chamber beforestart up Air leak at the suction pipe due to the followin...

Page 17: ...dispose of this product by means of the specific refuse collection structures indicated by the government orthe local governing authorities The user is invited to effect a proper waste separation in...

Page 18: ...S p A ELENCO COMPONENTI PARTS LIST ENG I T 18...

Page 19: ...S p A INGOMBRI DIMENSIONS ENG I T 19...

Page 20: ...S p A DIAGRAMMI DIAGRAMS DIAGRAMMA PORTATA FLOW RATE DIAGRAM DIAGRAMMA ASSORBIMENTI AMPERE DRAW DIAGRAM ENG I T 12V 24V 0 5 10 15 0 0 5 1 1 5 2 2 5 bar l min 0 2 5 5 7 5 0 0 5 1 1 5 2 2 5 bar A 20...

Page 21: ...ools and similar apparatus Part 2 Immunity Compatibilit elettromagnetica Requisiti per gli elettrodomestici gli utensili elettrici ed apparecchi similari Parte 2 Immunit Questa dichiarazione valida pe...

Page 22: ...S p A NOTE NOTES ENG I T 22...

Page 23: ......

Page 24: ...stro sito internet www marco it Marco S p A Via Mameli 10 25014 Castenedolo Brescia Italia tel 39 030 2134 1 Fax 39 030 2134 300 Property of MARCO S p A reproduction prohibited All rights reserved For...