Marco 1000674 Instructions Manual Download Page 7

1900051                                                                   REV.1     

         

Page 7 of 12 

 

 
 
 
 

MODES OF OPERATION (Service se tup setting 5) :  

The boiler can operate in 4 different modes: 
 

  HEAT FILL 

– Standard operation the boiler will take in water until the temperature in the tank 

drops, the inlet will close and the heating element is activated. When the temperature reaches 
the set temperature the inlet will reopen to take in more water. This cycle will continue until the 
Tank is Full.  

 

This mode is used to ensure that the water temperature is controlled within set values. 

 

  CONTINUOUS MODE 

– In this mode the boiler will take in water and activate the element until 

the tank is full and the temperature has reached the set temperature. Typically used in high 
demand situations where the temperature stability is not primary concern. 

 

  COOL MODE  

– In this mode the temperature can be adjusted up or down [Set-up function 

no.1.]  while in operation. Depending on the water level in the tank selecting a lower 
temperature will cause either a message to 

“DISPENSE WATER TO COOL THE TANK” or will 

automatically take in cooler water to reduce the temperature to the new set temperature. In 
applications where selecting different temperatures frequently is required this Cool Mode is 
best selected.  

 

Please note that Cool Mode will cause the boiler to operate at half the capacity (eg 10L boiler 
to operate as a 5L boiler). 

 

  MANUAL FILL 

– if the boiler is not plumbed into a water supply the operator must select 

Manual Fill mode for best operation of the boiler. In this mode the water is added manually by 
the operator. 
 
 

ECO MODE OPERATION:  

 
Note:

 In the COOL FILL mode [see Service setup setting No. 5] the ECO Mode is automatically 

selected. 

 

  All ECO Boilers use high grade insulation and it is applied to give a significant energy usage 

improvement over a standard water boiler. 

  The counter top 

range incorporates a ½ tank ‘ECO mode’ function. 

 

To enable the ‘ECO Mode’ press the button located below the ‘Ready’ indicator so that the leaf 
symbol illuminates green. 

  This mode saves energy by minimising the energy wasted during machine down-time.  

 

NOTE: The ECO mode is most effective in installations where the machine has a regular ‘off’ 
period. 

 

To achieve the most benefit from the energy saving ‘ECO Mode’ on your ECO boiler unit (10L 
variants only), the following method should be employed: 

o

  Towards the end of the boilers operating period for a given day, switch the machine to 

ECO Mode. Whilst maintaining water at preset value, the machine tank will slowly drop 
to half full, where it will remain. 

o

  During the 

‘off’ period as there is less water in the tank there will be less energy lost to 

the surrounding environment resulting in an energy saving. 

 

To disable simply press the ‘ECO Mode’ button again so that the leaf symbol is not illuminated 

 
 

Summary of Contents for 1000674

Page 1: ...ax 4EF8 E337347 4JD5 Marco Beverage Systems Limited 63d Heather Road Sandyford Industrial Estate Dublin 18 Marco Beverage Systems Limited Shire House Strixton Manor Strixton Wellingborough Northants NN29 7PA Ireland Tel 353 0 1 295 2674 Ireland Fax 353 0 1 295 3715 email sales marco ie www marco ie UK Tel 44 0 2072 744 577 UK Fax 44 0 2079 788 141 email sales marco bev co uk www marco bev co uk ...

Page 2: ...dren should be supervised to ensure that they do not play with the appliance In the event any wires are damaged such wires can only be replaced by experts or professional after service staff from the manufacturer after service department or similar function departments INSTALLATION DETAILS Electrical installation Electrical specification Machine type Rated power Plug type 1000677US 1000678US 2 9kW...

Page 3: ...Y The Boiler may now be used to dispense Hot Water to the preset factory settings o 95ºC o Push and Hold operation o Continuous flow no pulsing o Auto Heat Fill Mode NOTE Because the boiler is electronically controlled no priming is necessary The element cannot switch on until a safe level of water is reached EcoSmart FEATURES The EcoSmart Ecoboiler has many settable features which gives the opera...

Page 4: ...en view Description Default value No 1 Sets new tank temperature NOTE Temperature should never be set for more than 97 C because it may cause steam to be generated during the low pressure days Range 60 98 5 C Resolution 0 5 C 95 0 No 2 Sets dispense time Range 0 99 9 seconds 0 1 sec resolution 100 600 seconds 1 sec resolution For PUSH HOLD mode set to 0 default 00 0 No 3 Sets number of pauses duri...

Page 5: ...s is a factory setting and should only be changed by trained personnel Range 0 20 0 seconds Resolution 0 1 second 3 0 2 8kW 6 0 5 6kW 9 0 8 4kW No 4 Sets the time at which machine waits for the water too cool down after water intake Measured from the beginning of the water intake The value depends on tank size and element power This is a factory setting and should only be changed by trained person...

Page 6: ...in COOL FILL mode DISPENSE WATER TO COOL THE TANK Machine can not take more cold water to cool the tank because it is full Water needs to be dispensed to allow room for more cold water to come in and finish cooling process DESCALE TANK Descale timer elapsed Time to de scale the tank CHANGE FILTER Litres output exceeds set value Time to change the water filter CHECK LOW PROBE Low water level probe ...

Page 7: ...erate at half the capacity eg 10L boiler to operate as a 5L boiler MANUAL FILL if the boiler is not plumbed into a water supply the operator must select Manual Fill mode for best operation of the boiler In this mode the water is added manually by the operator ECO MODE OPERATION Note In the COOL FILL mode see Service setup setting No 5 the ECO Mode is automatically selected All ECO Boilers use high...

Page 8: ...ds Remove as much scale as possible by hand paying particular attention to level probes White plastic with steel tab Be very careful not to damage any attachments Use ScaleKleen Marco part No 8000270 or similar Follow instructions carefully Thoroughly clean and flush the machine before re use Follow installation and first time operation instructions CLEANING The exterior of these machines may be c...

Page 9: ...arranty Fitting a scale reducer is recommended especially in hard water areas This can reduce the build up of scale but may not stop it altogether The frequency that descaling is required depends on the local water supply hard water areas need more attention Descaling of the machine should ideally be carried out by qualified service personnel ...

Page 10: ...1900051 REV 1 Page 10 of 12 Intentionally Blank ...

Page 11: ...1900051 REV 1 Page 11 of 12 Intentionally Blank ...

Page 12: ...1900051 REV 1 Page 12 of 12 Intentionally Blank ...