Marchetti OLYMPO Instructions For Use And Maintenance Manual Download Page 4

4

www.marchetti.eu

1.  REFERENCE STANDARDS

-  Leg. Decree 09.04.2008 no. 81 (O.G. no. 101 dated 30.04.08) “Consolidating act on health and 

safety in the workplace”.

-  UNI EN 1004 (July 2005) “Mobile access and working towers) composed of prefabricated 

elements. Materials, dimensions, design loads, safety and performance requirements”;

-  EN 1298 (February 1996) “Mobile access towers. Regulations and guidelines for preparation 

of an instructions manual”;

-  Leg. Decree 06.09.2005 no. 206 (O.G. no. 235 on 08.10.05 – Ordinary Supplement no. 162) 

“Consumers’ Code”.

2.  DESIGNATION, CLASS, CAPACITY

OLYMPO working tower EN 1004 – 3 – 5 / 5 XXCD

manufactured in compliance with Leg. Decree 81/08 and Technical Standard UNI EN 1004;

Class of loads distributed uniformly equal to “3” (2.0 KN/m2);
-  Maximum height permitted of the working surface equal to 5 metres both outside and inside 

buildings. Inside is intended as without wind

-  The overall load permitted for each tower is therefore 200 kg.
-  The maximum number of surfaces loaded at the same time is 2.
-  The sum of the loads relating to each surface must not exceed the overall value of the load 

permitted for the scaffolding.

Summary of Contents for OLYMPO

Page 1: ...means working in compliance with the provisions of the current standard on health and safety in the workplace Leg Decree 09 04 2008 no 81 Code 11115 CUSTOMER ASSISTANCE DOCUMENT N 120 REV 2 DATED 08...

Page 2: ...ow the instructions as indicated Before any installation verify the integrity of each individual component Do not use damaged or not whole components The mobile access tower is made according to the s...

Page 3: ...TOWER DESIGN pag 8 CONFIGURATIONS UNI EN 1004 pag 9 6 ASSEMBLY AND DISMANTLING pag 10 6 1 General information pag 10 6 2 Preliminary tests pag 10 6 3 Assembly instructions pag 10 6 4 Dismantling instr...

Page 4: ...G no 235 on 08 10 05 Ordinary Supplement no 162 Consumers Code 2 DESIGNATION CLASS CAPACITY OLYMPO working tower EN 1004 3 5 5 XXCD manufactured in compliance with Leg Decree 81 08 and Technical Stan...

Page 5: ...prototype which has surpassed rigidity testing pursuant to Appendix A of the Technical Standard EN 1004 2005 and that it was subject with a positive outcome with the ASSESSMENT as outlined in point 1...

Page 6: ...4 2 Maximum heights of the configuration EN 1004 The maximum height of the work platform without using the stabilizer braces is 1 60 metres maximum tower height 2 90 metres The maximum height of the...

Page 7: ...1093 Short toeboards 75 0 75 2 2 2 6 11092 Long toeboards 180 3 00 2 2 2 21324 Guardrail 7 33803 Single parapet 2 00 2 2 2 20770 Stabilizer braces 8 20765 Stabilizer brace 35 Normal 9 80 0 4 4 9 31377...

Page 8: ...8 www marchetti eu OLYMPO TOWER DESIGN BASE TOWER FINAL TOWER GUARDRAIL WORK PLATFORM STABILIZERS BRACES 14 3 2 2 12 11 10 4 13 1 8 9 7 5 6 9...

Page 9: ...H Tower 2 00 H Working 0 80 A1T H Tower 2 90 H Working 1 60 A2 H Tower 3 70 H Working 2 40 A2T H Tower 4 60 H Working 3 30 A3 H Tower 5 40 H Working 4 10 A3T H Tower 6 20 H Working 5 00 CONFIGURATIONS...

Page 10: ...embly operations can only start in the absence of wind d all the elements must be checked accessory tools and safety equipment to assemble the tower are available on site e The verticality of the mobi...

Page 11: ...mentsofthescaffolding on the fourth rung from the bottom of the first two side frames firstly position the 2 long toeboards parallel to the treadable surface then the 2 short toeboards fitting them in...

Page 12: ...he joint on the riser of the tower at a height to fit the upper vertical part of the brace Repeat the operation with a second joint in the same riser distancing it adequately from the first to fit the...

Page 13: ...g the necessary operations in the inverse order to those for assembly the elements composing the towers must be lowered from above using ropes or other suitable devices avoiding sudden impact with the...

Page 14: ...re a the mobile access towers can only be moved manually on compact smooth surfaces free of obstacles perfectly level and in the absence of wind b before moving lift the adjustable feet off the ground...

Page 15: ...ore use Strictly complying with this manual means operating in accordance with the provisions of existing legislation on health and safety at work Legislative Decree 09 04 2008 no 81 Instructions for...

Page 16: ...Leg Decree 81 08 but not with UNI EN 1004 they must have the base wheels braked during use and positioned on an already perfectly level floor and have stabiliser feet when present removed to the maxim...

Page 17: ...ope anchored on top of the last upright of the last side support frame and under the wheel support block of the base section The fall proof device the safety harness and the holding rope must be certi...

Page 18: ...welding Lubrication of tightening screws Lubrication of pins and sleeves Efficiency of wheels and braking devices Integrity of work platforms Integrity of railings Integrity of toe boards Integrity of...

Reviews: