March Pumps TE-7.5-MD Series Manual Download Page 1

Series TE-7.5-MD Pumps w/1 Phase Motor

DESCRIPTION & OPERATION:

 Series 7.5 are centrifugal magnetic drive pumps. See the parts list 

for a breakdown of parts. Pumps are not self-priming, lack a suction lift, and thus require a 

flooded 

suction

.  Pumps 

cannot  be  run  dry

  because  the  impeller  requires  the  liquid  being  pumped  for 

lubrication. The direction of motor rotation should be clockwise when facing the inlet of the pump. 
For  liquids  with  a  specific  gravity  greater  than  water,  have  a  higher  viscosity,  or  for  elevated 
temperatures,  a  trimmed  impeller  may  be  necessary.  For  application  assistance,  contact  March 
Pump.

 

 

Model Abbreviations:

 K: Kynar, P: Polypropylene 

 

ELECTRICAL:

 The motor is 1 phase 115/230 Volt 60 Hz, 110/220 Volt 50 Hz.  The motor is U.L. 

listed and rated as continuous duty.

 

 

CAUTION IN ASSEMBLY & DISASSEMBLY: 

The magnetic coupling in the pump is strong enough 

to warrant caution. When servicing the pump, the attraction of the impeller magnet and drive magnet 
may pull the impeller from your grasp. When assembling, hold onto the outer diameter of the impeller 
vanes with both hands and gently engage the impeller into the magnet field. Hold the impeller firmly 
and resist the magnetic attraction as you slowly put the impeller back in. The magnetic forces are 
strongest between 1/3 to 2/3 of engagement and will diminish when the magnets become aligned. 
Do not allow the impeller to snap into the rear housing, doing so may result in damage. Exercise 
caution in placing any of the magnets near steel, tools, or other sensitive instruments as doing so 
may result in damage or personal injury. When attaching drive magnet to motor shaft, position the 
face of the drive magnet 5/32 inch above the face of the motor bracket.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SPECIFICATIONS

 

TE-7.5K-MD

 

TE-7.5K-MD with Flanges

 

TE-7.5P-MD

 

TE-7.5P-MD with Flanges

 

 

 

Product # 

0156-0001-0200 

0156-0001-0270 

0156-0059-0400 

0156-0059-0470 

Inlet - Outlet 

2” MPT – 1-1/2” MPT 

2” Inlet Flange – 1-1/2” Outlet Flange 

2” MPT – 1-1/2” MPT 

2” Inlet Flange – 1-1/2” Outlet Flange 

Max Internal Pressure 

60 psi (413 kPa) 

60 psi (413 kPa) 

60 psi (413 kPa) 

60 psi (413 kPa) 

Max Liquid Temperature 

190 °F (87 °C) 

190 °F (87 °C) 

190 °F (87 °C) 

150 °F (65 °C) 

Overall Size (H x W x L) 

10” (25.4 cm) x 9.53” (24.2 cm) x 19.58” (49.47 cm)  10.13” (25.7 cm) x 9.53” (24.2 cm) x 20.93” (53.2 cm)  10” (25.4 cm) x 9.53” (24.2 cm) x 19.58” (49.47 cm)

 

10.13” (25.7 cm) x 9.53” (24.2 cm) x 20.93” (53.2 cm)

 

MODEL 

60 Hz 

50 Hz 

Packed Weight 

Max Flow 

Max Head 

ELECTRICAL 

Max Flow 

Max Head 

ELECTRICAL 

Threaded 

Flanges 

gpm  lpm  ft 

psi 

Ph 

Hp  kW

 

Rpm  gpm  lpm 

ft 

psi 

Ph 

Hp  kW  Rpm 

lbs 

kg 

lbs 

kg 

TE-7.5K-MD 

82  310  85  36.8  26 

115  22 

2  1.491 3450  70.8  268  59  25.6  18 

100  20 

1.5  1.118 2850 

64.80 

29.39 

65.8 

29.84 

230  11 

200

 

10 

TE-7.5P-MD 

82  310  85  36.8  26 

115  22 

2  1.491 3450  70.8  268  59  25.6  18 

100  20 

1.5  1.118 2850 

64.80 

29.39 

65.8 

29.84 

230  11 

200

 

10 

All specifications & data are based on pumping water & are intended as a guideline only. Specifications may vary with different motors. 

Reviews: