9000 R Series IP Recorder with RAID Installation Guide
20
Feature Overview
Power Supply Module LEDs
Each power supply module has an LED to indicate status.
Note:
The following photos do not show the power cords.
The following table lists the details of the LEDs for the 2U power supply modules.
2U Recorder — Power Supply Module LED Status
The following table lists the details of the LEDs for the 1U power supply modules.
1U Recorder — Power Supply LED Status
LED State
Power Supply Condition
Off
No AC power available.
Flashing Green
AC power on standby - the system is in the process of shutting down after using the
power On/Off pinhole to safely shut down the recorder unit.
Solid Green
AC power available, module is functioning correctly.
Flashing Amber
Power supply warning, but the power supply continues to operate.
(Temperature too high, current too high, fan too slow.)
Solid Amber
AC cord unplugged, AC power lost from this module, or module failure.
Power supply critical event.
LED State
Power Supply Condition
Off
No AC power available or module failure.
Green
AC power available, module is functioning correctly.
2U power supply module
1U power supply module
Status LED