4. Connecting the Input and Output Power

1.

Open

 

/

 

disconnect

 the upstream breaker feeding utility power to

 

the s

ignal cabinet.

2.

Disconnect the HOT wire (Black

 or Red

) connected between 

utility and

 

the 

traffic cabinet.

3.

Run

 a 

#6 - #10 AWG

 wire 

(Black or Red) 

from the 

Main AC 

utility source

 

Bus Bar

 to

 

the 

VAC IN 

terminal

 

on PTS. Run 

#6 - 

#10 AWG

 

wires from the

 

neutral and ground bus bars of traffic 

cabinet to

 

PTS neutral &

 

ground terminal blocks. Torque the 

PTS terminal

 

block to a

 

maximum of 10.0 lb-in (1.1 Mm).

4.

Connect a 

#6 - #10 AWG

 wire 

(Black or Red) 

from the 

VAC 

OUT

 at the

 

PTS to the signal cabinet. Torque the PTS terminal 

block to a

 

maximum of 10.0 lb-in (1.1 Mm).

 This is power to the 

Load.

Keyed 

AC INPUT / AC OUTPUT

 Connectors 

and PTS Connection. (Images shown below) 

PTS BYPASS CONTROL

 

AC INPUT / AC OUTPUT

 

Cable Connections 

From PTS 

To UPS 

UPS IN 

UPS AC INPUT 

UPS OUT 

  UPS AC OUTPUT 

BYPASS CONTROL (48VDC) 

  PTS 

AC INPUT / OUTPUT TERMINAL 

4