53
11. ABOUT REPLACE THE MICROPROCESSOR WITH A NEW ONE
When replaced of the µ-PRO (Microprocessor) or the Flash ROM, confirm contents of the following.
PWB
Name
Pos.
No.
Description
After
replaced
Remark
µ-PRO
U12 ATMEGA16L-8AU 8BIT 16K FLASH TQFP44P
B
After replaced
A : Mask ROM (With software).
No need write-in of software to the microprocessor.
B : Flash ROM (With software).
Usually, no need write-in of software. But, when the software was updated, you should be write-in of the
new software to the microprocessor or flash ROM. Please check the software version.
C : Empty Flash ROM (Without software).
You should be write-in of the software to the microprocessor or flash ROM. Refer to "Update procedure" or
"writing procedure", when you should be write-in the software.
マイコン等を交換した場合の対応について
µ-PRO(
マイコン
)
および
Flash ROM
等を交換した場合の対応方法を下記の記載します。
PWB
Name
Pos.
No.
Description
交換時の
対応
備考
µ-PRO
U12 ATMEGA16L-8AU 8BIT 16K FLASH TQFP44P
B
交換時の対応
A : Mask ROM (
ソフトウェア書き込み済み
)
交換時にソフトウェアの書き込みは必要ありません。
B : Flash ROM (
ソフトウェア書き込み済み
)
バージョンアップにより交換時にソフトウェアの書き換えが必要な場合があります。バージョンの確認をして
ください。
C :
空
ROM (Flash ROM)
交換時必ずソフトウェアの書き込みが必要になります。
Update
、書き込み方法を参照してください。
Summary of Contents for VS3002
Page 7: ... 6 Click the Install 7 Click the Finish 6 Installをクリックします 7 Finishをクリックします ...
Page 16: ...18 17 INPUT 3 TO HDMI PWB 3 3 INPUT 4 INPUT 5 INPUT 6 HDMI PWB 2 3 ...
Page 17: ...19 20 INPUT 1 OUTPUT 2 OUTPUT 1 INPUT 2 FROM HDMI PWB 2 3 HDMI PWB 3 3 ...
Page 18: ...22 21 TO FRONT PWB FROM SMPS UNIT TO HDMI PWB 1 3 µ PRO PWB 1 2 ...
Page 20: ...26 25 TO µ PRO PWB 1 2 TO µ PRO PWB 2 2 TO STBY SW PWB FRONT PWB ...
Page 21: ...27 28 FROM FRONT PWB T1 EE2525V 5 5 PIN ORTP 692 STBY SW PWB SMPS UNIT UNIT ASSY is replaced ...