15
[B] Color Temperature Adjustment Procedure
Before pressing the
ENTER
button, turn the
color temperature sensor over on its dark side
as shown in the below figure, to prevent
outside light from penetrating to the sensor’s
condenser.
5.
Press the
ENTER
button. The below message
appears on the screen for a few seconds as
the sensor is being calibrated.
6.
Position the lamp so that its light passes
through the center of the lens. This is
necessary in order to calibrate color
temperature correctly. First, turn the lens shift
knob all the way to the left so that the lens
lowers to the lowest position. Then, turn it five
and a half turns to the right to raise the lens.
In this position, the light of the lamp passes
almost through the center of the lens.
Note:
Color temperature cannot be correctly
calibrated unless the lens is properly
positioned.
Initializing...
After replacing the lamp or in other cases where
the lighting changes, color temperature can be
adjusted using the color temperature sensor. In the
adjustment procedure, you must first initialize the
sensor itself before adjusting color temperature. It
takes about 10 minutes from when the power to
the projector is activated for the lamp’s brightness
to stabilize. Wait for lamp brightness to stabilize
before adjusting color temperature.
1.
Connect the cable of the color temperature
sensor to the RS-232C port.
2.
4.
Color Temperature Adjustment
Condenser
Press the cursor button
B
(RIGHT).
The below message appears on the screen.
3.
With the direction buttons, up, down, left and
right, select "Color Temp Calibration" under
"Color Temp."
Pressing the 3 buttons
LEFT
,
ENTER
,
INPUT
on the unit within 10 seconds after
turning on power or RC5 code "16 63 63"
is sent using service remote, and turn into
the service mode.
(Part no. : 00MZK09AV0070)
Press the
ENTER
button. The below message
appears on the screen.
Press "Enter" to start
Initialize
Color Temp. Calibration?
Yes
No
Press "Enter" to start