SPECIAL MODE
Special mode setting button
b
No. 1 : Insert the AC plug while pressing "
A
" button, and wait for more than 3 seconds.
b
No. 2, 3 : Insert the AC plug while pressing "
A
" and "
B
" buttons together, and wait for more than 3 seconds.
b
No. 4, 5 : While the power is on, hold down buttons "
A
" and "
B
" for at least 3 seconds .
No.
Mode
Button A Button B
Descriptions
1 Selecting the Mode1 for Service-
related
Power
-
Service mode information is selected in Service-related selection mode 1.
Service-related modes: No. 1-1 - No. 1-6 (See
1. Selecting the Mode1 for Service-related
)
1-1 Version Display Mode
↑
-
The firmware version is shown on the display. (See
1-2 IR Control Test
↑
-
Since this mode is only for production/development, the detailed information is not provided.
1-3 Protection history display mode
↑
-
Displays the protection occurrence history. (See
1-3. Protection History Display Mode
)
1-4 All Device DPMS Update mode
↑
-
Standard updates are now performed through OTA. (See
6. Normal Firmware Update Method from OTA (NETWORK MODULE)
1-5 Display check mode
↑
-
Since this mode is only for production/development, the detailed information is not provided.
1-6 Initialize
↑
-
Initialize the backup data for the MCU and network module.
(See
)
2 Factory Initialization Mode
(Factory Reset)
SOURCE
DIRECT
BACK
Initialize the backup data only for MCU. Network function settings are not initialized.
(See
2. Factory Initialization Mode
)
3 Firmware Factory Restore
POWER
BACK
Used when replacing the Network module.
(See
)
4 Network Function Reset
POWER
BACK
Network module backup data is initialized.
(See
)
5 Selecting the Mode2 for Service-
related
POWER
ENTER
Service mode information is selected in Service-related selection mode 2.
Service-related modes: No. 5-1 - No. 5-2 (See
5. Selecting the Mode2 for Service-related
)
5-1 LEGO Log Capture Mode
↑
↑
Acquires the Network Module log. The log is deleted when the Network Module is deleted.
(See
)
5-2 Shipping Reset
↑
↑
Since this mode is only for production/development, the detailed information is not provided.
BACK
SOURCE DIRECT
X