SERVICE MODE
Microprocessor (U1001) version chseck
(1) Press the POWER button with pressing the SOURCE DIRECT button on the unit.
(2) The firmware version is displayed on the front LED. (Display time is only for 3 seconds.)
The firmware version is displayed in the lighting position of LED.
Ex. :
Light up RECORDER-2 [1 ], Version : 1
Light up RECORDER-2 [1 ] and AUX/DVD [4 ], Version : 5
Light up RECORDER-2 [1 ] and CD [8 ], Version : 9
(3) Each LED light up then all LED light up.
(4) Turn off the power to quit Service Mode. (The unit to the default status)
Version :
16 8 4 2 1