SERVICE MANUAL
PAGE:3
SERVICING PRECAUTIONS
CAUTION!!
Before servicing receivers covered by this service manual, read and follow the SAFETY
PRECAUTIONS on page 2 of this publication.
General Servicing Precautions
1.Always unplug the receiver AC power cord from AC power source before;
Removing or reinstalling any component, circuit board module or any other receiver assembly.
Disconnecting or reconnecting any receiver electrical plug or other electrical connection.
Connecting a test substitute in p
a.
b.
c.
arallel with an electrolytic capacitor in the receiver.
CAUTION!! A wrong part substitution or incorrect polarity installation of electrolytic capacitors
may result in an explosion harzard.
2.Do not spray chemicals on or near this receiver or any of its assemblies.
3.Do not defect any plug/socket voltage interlocks with which receivers covered by this service
manual might be equipped.
4.Always connect the test receiver ground lead to the receiver chassis ground before
connecting the test receiver positive lead. Always remove the test receiver ground lead last.
5.Do not connect the test fixture ground strap to power supply heatsink in this receiver
Electrost atically Sensitive(ES) Devices
Some semiconductor(solid state) devices can be damaged easily by static electricity. Such
components commonly are called Electrostatically Sensitive(ES) Device.Examples
Circuit Board Foil Repair
Excessive heat applied to the copper foil of any printed circuit board will weaken the adhesive
that bonds the foil to the circuit board causing the foil th separate from or “lift-off” the board.
The following guidelines and procedures should be flollowed whenever this condition is
encountered.
At IC Connections
To repair a defective copper pattern at IC connections use the following procedure to install a
jumper wire on the copper pattern side of the circuit board.(Use this technique only on IC
connections.)
1.Carefully remove the damaged copper pattern with a sharp knife.(Remove only as much
copper as absolutely necessary.)
2.Carefully scratch away the solder resist and acrylic coating(if used) from the end of the
remaining coopper pattern.
3.Bend a small “U” in one end of a small guage jumper wire and carefully crimp it around the IC
pin.
4.Route the jumper wire along the path of the out-away copper pattern and let it overlap the
previously scraped end of the good copper pattern. Solder the overlapped area and clip off any
excess jumper wire.
Summary of Contents for LC3050
Page 24: ...SERVICE MANUAL PAGE 22 PCB LAYOUT CONTROL PCB 1 TOP COMP PATTERN 2 BOTTOM COMP PATTERN ...
Page 25: ...SERVICE MANUAL PAGE 23 PCB LAYOUT Main PCB TOP COMP ...
Page 26: ...SERVICE MANUAL PAGE 24 PCB LAYOUT Main PCB TOP PATTEN ...
Page 27: ...SERVICE MANUAL PAGE 25 PCB LAYOUT Main PCB BOTTOM COMP ...
Page 28: ...SERVICE MANUAL PAGE 26 PCB LAYOUT Main PCB BOTTOM PATTEN ...