Overall preset saving and restoration, suitable for machine migration or OEM
customers writing data in multiple machines
Provides many plug-ins, currently including 48kHz sampling rate FIR filter and
96kHz extended bandwidth FIR filter, the default is 48kHz sampling rate, 1024Taps
per channel; when a high number of taps is required, multiple channels can be
aggregated into one channel to achieve the highest 4096Taps FIR filter, enough to
cover the whole frequency band processing
5
6
The output part, including gain, polarity, delay, IIR high and low pass filters, can be
switched to MIR linear phase filter, or FIR filter can be used. Contains three dynamic
processing modules: 8-band PEQ, RMS compressor, peak limiter, and hard limiter.
7
Backup
Restore
Summary of Contents for MIR480I