Mara SCC-42A065 User Manual Download Page 6

 

 

EN 

  Mode 

Battery size (Ah) 

Explanation 

 

1.6 ~14Ah 

Small Battery 

14.4 Voltage max, Current 0.8A 

For  charging  12V  lead-acid  batteries. 

After selecting it, the LED will then light up 

as green. 

 

14 ~110Ah 

Normal Battery 

14.4 Voltage max, Current 4.3A   

For charging 12V lead-acid batteries. After 

selecting it, the LED will then light up as 

green. 

Maintain 

1.6~160Ah 

Maintain(for SCC-42A065) 

14.4 Voltage max, Current 2A 

For maintaining 12V lead-acid batteries. 

and after selecting it, the LED will then light 

up as green.

 

Maintain 

6~110Ah 

Maintain(for SCC-41A065) 

14.4 Voltage max, Current 2A 

For maintaining 12V Lithium ion batteries 

(LiFePO4), 

after selecting it, the LED will then light up 

as green.

 

 

LFP 

6 ~60Ah 

Lithium ion Battery 

14.4 Voltage max, Current 4.3A   

For charging 12V Lithium ion batteries 

(LiFePO4), after selecting it, the LED will 

then light up as green. 

CHARGING STEPS 

 

Step 1: Diagnosis 

C

hecks the battery’s present condition, including voltage, battery health, and state-of-charge, 

Summary of Contents for SCC-42A065

Page 1: ...arger SCC 42A065 SCC 41A065 PLEASE SAVE THIS USER MANUAL AND READ BEFORE EACH USE This manual will guide you in how to use the charger safely and effectively Please read and follow these instructions...

Page 2: ...sk of electric shock or fire 10 To reduce the risk of electric shock pull out charger from outlet before attempting any maintenance or cleaning Turning off controls will not reduce this risk 11 The su...

Page 3: ...tended to supply power to a low voltage electrical system in addition to an application of starter motor Do not use battery charger for charging dry cell batteries that are used with home appliances n...

Page 4: ...4 EN OVERVIEW for SCC 41A065 1 Mode Button 2 Error LED 3 LFP Battery program INCLUDE ACCESSORIES Jump Booster Cable Jump Eyelet Cable 4 Maintain Program 5 Power LED 6 Charging programs...

Page 5: ...to press the MODE button to combine charging program with charging options Press the MODE button several times until the desired combination of charging program and options are lit up 4 Follow the 4...

Page 6: ...tage max Current 2A For maintaining 12V lead acid batteries and after selecting it the LED will then light up as green Maintain 6 110Ah Maintain for SCC 41A065 14 4 Voltage max Current 2A For maintain...

Page 7: ...e level of battery capacity until removing the clamp Maintain After the maintain mode is pressed 2 Amp charger starts to charge depending on the optimized output program and maintain the battery in a...

Page 8: ...ck the connection Battery voltage is too low Check battery Battery voltage is too high Check Battery Over heated Unplug the power plug it in again after cooling down For more information about the pos...

Reviews: