![Maplin Gadget N35HN Instruction Manual Download Page 2](http://html1.mh-extra.com/html/maplin-gadget/n35hn/n35hn_instruction-manual_1724225002.webp)
Press and hold
FUNC
button for 5 seconds to clear max. line power display in this mode
5. Press
FUNC
button once again and release, the meter will display current clock and accumulative power factor
6, Press
FUNC
button once again and release, the meter will display current clock, accumulative CO2 discharge and power factor.
7. Press
FUNC
button once again and release, the meter will display total usage time and total electricity cost
8. Press
FUNC
button once again and release, the meter will display total usage time at price 1 and total electricity cost at price 1
9. Press
FUNC
button once again and release, the meter will display total usage time at price 2 and total electricity cost at price 2
10. Press and hold
FUNC
button for 5 seconds to clear accumulative total electricity usage and total electricity cost while displaying
total cost and usagemode or total electricity cost at either price 1 or price 2
11. LCD display
----
should your total electric usage in either units or cost exceed the maximum settings, the word
OVER
will flash
SETTING CURRENT CLOCK
1. Press
FUNC
button until the
CLOCK
displays on the LCD
2. Press
SET
button once: the “
WEEK DAY
“ will flash, ( if the clock changes to
SET
mode,you can set the current time)
3. Press
UP
button to set the “
WEEK DAY
“
4. Press
SET
button once again and release: the “
HOUR
“ will flash (the “
WEEK DAY
“ will stop flashing but remain on the display)
5. Press
UP
button to set the “
HOUR
“
6. Press
SET
button once again and release: the “
MINUTE
“ will flash (the “
HOUR
“ will stop flashing but remain on the display)
7. Press
UP
button to set the “
MINUTE
“
8. Press
SET
button once time again and release: the time will return to
CLOCK
display mode
9. Press
UP
button when the
CLOCK
is displayed to change betwween 12/24 hour mode. To reset the time, repeat the above steps
Now plug the meter into a normal 230/240V mains socket, plug in an appliance that you want to use and turn the mains power on.
The meter will begin to measure the consumption of the appliance and inform you which equipment uses too much electricity.
SETTING PRICE OF COST/kWh & OVER LOAD CURRENT
Press and hold
FUNC
button for 5 seconds while the LCD is displaying voltage, current or power mode
1.Setting
price 1
:
a. Press
SET
button once and release:
SET
display, the first digital
COST/kWh
flash, press
UP
button to set it
b. Press
SET
button once again and release: the second digital
COST/kWh
flash, press
UP
button to set it
c. Press
SET
button once again and release: the third
COST/kWh
flash, press
UP
button to set it
d. Press
SET
button once again and release: the fourth
COST/kWh
flash, press
UP
button to set it
e. Press
SET
button once again and release: the decimal point on the
COST/kWh
flash, press
UP
button to set it
f. Press
SET
button once again and release: the weekday will flash, press
UP
button to set it
g. Press
SET
button once again and release: the hour of
ON TIME will
flash, press
UP
button to set it
h. Press
SET
button once again and release: the minute of
ON TIME will
flash, press
UP
button to set it
2.Setting
price 2
:
Press
FUNC
button once and release after finishing setting price 1. To set price 2, repeat the above steps
3.Setting
OVER LOAD
current data:
Press
FUNC
button once and release after finishing setting price 2
a. Press
SET
button once and release:
SET & AMP show on the
display, the first digital
MAX. LOAD
flashes, press
UP
button to set it
b. Press
SET
button once again and release: the second digital
MAX. LOAD
flashes, press
UP
button to set it
c. Press
SET
button once again and release: the third
MAX. LOAD
flashes, press
UP
button to set it
d. Press
SET
button once again and release: the fourth
MAX. LOAD
flashes, press
UP
button to set it
The
OVER LOAD WARNING
will flash when the load exceeds the set data. The buttons will not work if this happens. You must
unplug the appliance or set the OVER LOAD data again
STAND BY MODE:
The LCD will turn off once the meter has been unplugged from the mains for 10 seconds. Press any key to switch it back on again
SPECIFICATIONS:
Power supply: AC 240 V 50Hz Maximum load: 13A / 3120W
Voltage range: AC 200 - 276 V Voltage ac/-1.5%
Ccurrent range: 0.001 - 16A Current accuracy: +/-0.5%
Power range: 0.1 - 3680W Power accuracy: +/-0.5%
Accumulative electricity usage range: 0 -9999.9kWh Frequency range: 45 - 65Hz
Clock accuracy: +/- 1 minute per month Power cost: <0.5W
Operating temperature: -10
o
C to +40
o
C Battery: 3.6V NiMH rechargeable battery
WEEE Directive & Product Disposal
At the end of its serviceable life, this product should not be treated as household or general waste. It should be handed over to
the applicable collection point for the recycling of electrical and electronic equipment, or returned to the supplier for disposal.
Internal / Supplied Batteries
• This symbol on the battery indicates that the battery is to be collected separately.
• This battery is designed for separate collection at an appropriate collection point.