Unpacking the Unit 

Carefully unpack the HMI. Check all material in the container against the 
packing list. Maple Systems will not accept responsibility for shortages 
against the packing list unless notified within 30 days. The equipment 
and accessories were inspected and tested by Maple Systems before 
shipment. Examine the equipment carefully; if any shipping damage is 
evident, notify the carrier immediately. Maple Systems is not responsible 
for claim negotiations with the carrier. Save the shipping container and 
packing material in case the equipment needs to be stored, returned to 
Maple Systems, or transported for any reason. 

 

Packing List 

HMI5000L Series Touchscreen 
Power Connector 
Mounting Clamps

 

USB Stick Clamp and Spare Fuse (Not on all models) 
HMI5000L Series Installation Guide 

 

Warranty 

Maple Systems warrants each product to be free from electrical and 
mechanical defects in materials and workmanship for a period of one (1) 
year for the LCD display and two (2) years for all other parts and labor 
from the date of shipment.  

This warranty does not apply to defects in the Products caused by 
abuse, misuse, accident, casualty, alteration, negligence, repair not 
authorized by Maple Systems, use on current or voltages other than 
specified by Maple Systems, or application or installation not in 
accordance with published instruction manuals. This warranty is in lieu of 
any other warranty either expressed or implied. 

Maple Systems liability is limited to the repair or replacement of the 
Product only, and not costs of installation, removal, or damage to user 
property or other liabilities. 

If Maple Systems is unable to repair or replace a nonconforming product, 
a refund may be offered in the amount paid to Maple Systems for such 
product in full satisfaction of its warranty obligation. Maximum liability of 
Maple Systems is the cost of the product.  

Summary of Contents for HMI5097XL

Page 1: ...ort Center section of the Maple Systems website www maplesystems com The Support Center provides links to information such as Manuals FAQs Technical Notes Training Videos Sample Projects Controller In...

Page 2: ...rranty Maple Systems warrants each product to be free from electrical and mechanical defects in materials and workmanship for a period of one 1 year for the LCD display and two 2 years for all other p...

Page 3: ...quirements as set forth in the EN55022 Emissions and EN55024 Immunity standards The products are designed to withstand electrical noise in harsh industrial environments They also conform to requiremen...

Page 4: ...ression devices Safety Precautions Please observe the following precautions and ensure compliance with all local and national electrical standards when installing the HMI Failure to comply with these...

Page 5: ...wered equipment Cover any equipment used in the enclosure that operates at high frequency or high current levels with a grounded metal shield Power Supply Selection The power supply used to power the...

Page 6: ...grounded to control panel Ground strap Quiet ground isolated AC Power Line Filter HMI Power Supply Shielded power cable Control panel is tied to a reliable earth ground 2 1 3 4 5 rear side HMI5100L 1...

Page 7: ...round Note If the control panel is made of a non conductive material it is essential that the chassis ground terminal of the HMI is connected to a clean earth ground point located close to the panel C...

Page 8: ...cable from the HMI to the power supply The power cable should not be any longer than necessary 2 Install the cable wires referencing the chart below with colors shown for Maple Systems Cable 6030 000...

Page 9: ...ches pits and other features that prevent the gasket from sealing properly If the panel or mounting surface is not uniform thick flat stiff or smooth enough then a sealant such as silicone may be requ...

Page 10: ...y the switch or router USB A USB driver included with the EZwarePlus software must be installed when downloading from the PC to the HMI via USB connection Caution When connecting two powered devices v...

Page 11: ...Hide System Toolbar Hides the arrow in the bottom right corner of the screen that accesses the System Toolbar same as Hide System Toolbar in System Parameters and LB9020 Boot Loader mode This mode fo...

Page 12: ...ing from the HMI due to vibration Steps 1 Insert the USB stick connector into the clamp and secure with the included zip tie 2 Press the spring and insert the USB stick into the USB port Note The USB...

Page 13: ...uts Pin COM1 RS 232 COM1 RS 485 4 wire COM1 RS 485 2 wire COM3 RS 485 2 wire 1 RX TX RX 2 RX TX RX 3 TX 4 TX 5 GND 6 TXD 7 TX RX 8 TX RX 9 RXD DE9P HMI5043L HMI5043LB HMI5121XL HMI5150XL DE9S DE9P Pin...

Page 14: ...rial Port Pinouts cont Pin COM2 RS 485 2 wire COM2 RS 485 4 wire COM3 RS 485 2 wire CAN Bus HMI5097XL only 1 TX RX RX 2 TX RX RX 3 TX 4 TX 5 GND 6 TX RX 7 CAN_L 8 CAN_H 9 TX RX Pin COM1 RS 232 1 2 RXD...

Page 15: ...HMI5000L Installation Guide 15 1010 1018 Rev 06 www maplesystems com...

Page 16: ...2015 Maple Systems Inc All rights reserved Maple Systems Inc 808 134 th Street SW Suite 120 Everett WA 98204 7333 Phone 425 745 3229 Email maple maplesystems com Web www maplesystems com...