Maple Systems HMI5097XL Installation Manual Download Page 1

1010-1018 Rev 06                                                                          www.maplesystems.com 

Introduction 

Thank you for purchasing a Maple Systems HMI5000L Series graphic 
industrial operator interface terminal. This booklet describes the steps 
necessary for installing the HMI5043L, HMI5043LB, HMI5070L, 
HMI5070LB, HMI5070NL, HMI5097XL, HMI5097NXL, HMI5100L, 
HMI5121XL, and HMI5150XL models. The HMI5000L Series 
touchscreens are configured using the EZwarePlus software (purchased 
separately). 

For information on programming and configuring the HMI, please refer to 
the 

EZwarePlus Programming Manual

 (P/N 1010-1015) available on 

the EZware software DVD.  

For additional information, please refer to the Support Center

 

section of 

the Maple Systems website, www.maplesystems.com. The Support 
Center provides links to information such as Manuals, FAQs, Technical 
Notes, Training Videos, Sample Projects, Controller Information Sheets, 
and Controller Cables. 

Static Awareness 

Do NOT remove the rear cover of the HMI5000L Series product 

– doing 

so will void the warranty. When the rear cover is removed the circuitry 
inside is exposed to possible damage by electrostatic discharge during 
handling. 

Minimize the possibility of any electrostatic discharge by: 

 

Handling the HMI at a static-free, grounded workstation. 

 

Discharging personal static by grounding yourself prior to 
handling the HMI. 

 

Connecting the chassis ground (FG or 

) connector of the HMI 

to a clean earth ground. 

 

Placing the HMI in an antistatic bag during transport. 
 

HMI5000L Series 

Installation Guide 

 

Summary of Contents for HMI5097XL

Page 1: ...ort Center section of the Maple Systems website www maplesystems com The Support Center provides links to information such as Manuals FAQs Technical Notes Training Videos Sample Projects Controller In...

Page 2: ...rranty Maple Systems warrants each product to be free from electrical and mechanical defects in materials and workmanship for a period of one 1 year for the LCD display and two 2 years for all other p...

Page 3: ...quirements as set forth in the EN55022 Emissions and EN55024 Immunity standards The products are designed to withstand electrical noise in harsh industrial environments They also conform to requiremen...

Page 4: ...ression devices Safety Precautions Please observe the following precautions and ensure compliance with all local and national electrical standards when installing the HMI Failure to comply with these...

Page 5: ...wered equipment Cover any equipment used in the enclosure that operates at high frequency or high current levels with a grounded metal shield Power Supply Selection The power supply used to power the...

Page 6: ...grounded to control panel Ground strap Quiet ground isolated AC Power Line Filter HMI Power Supply Shielded power cable Control panel is tied to a reliable earth ground 2 1 3 4 5 rear side HMI5100L 1...

Page 7: ...round Note If the control panel is made of a non conductive material it is essential that the chassis ground terminal of the HMI is connected to a clean earth ground point located close to the panel C...

Page 8: ...cable from the HMI to the power supply The power cable should not be any longer than necessary 2 Install the cable wires referencing the chart below with colors shown for Maple Systems Cable 6030 000...

Page 9: ...ches pits and other features that prevent the gasket from sealing properly If the panel or mounting surface is not uniform thick flat stiff or smooth enough then a sealant such as silicone may be requ...

Page 10: ...y the switch or router USB A USB driver included with the EZwarePlus software must be installed when downloading from the PC to the HMI via USB connection Caution When connecting two powered devices v...

Page 11: ...Hide System Toolbar Hides the arrow in the bottom right corner of the screen that accesses the System Toolbar same as Hide System Toolbar in System Parameters and LB9020 Boot Loader mode This mode fo...

Page 12: ...ing from the HMI due to vibration Steps 1 Insert the USB stick connector into the clamp and secure with the included zip tie 2 Press the spring and insert the USB stick into the USB port Note The USB...

Page 13: ...uts Pin COM1 RS 232 COM1 RS 485 4 wire COM1 RS 485 2 wire COM3 RS 485 2 wire 1 RX TX RX 2 RX TX RX 3 TX 4 TX 5 GND 6 TXD 7 TX RX 8 TX RX 9 RXD DE9P HMI5043L HMI5043LB HMI5121XL HMI5150XL DE9S DE9P Pin...

Page 14: ...rial Port Pinouts cont Pin COM2 RS 485 2 wire COM2 RS 485 4 wire COM3 RS 485 2 wire CAN Bus HMI5097XL only 1 TX RX RX 2 TX RX RX 3 TX 4 TX 5 GND 6 TX RX 7 CAN_L 8 CAN_H 9 TX RX Pin COM1 RS 232 1 2 RXD...

Page 15: ...HMI5000L Installation Guide 15 1010 1018 Rev 06 www maplesystems com...

Page 16: ...2015 Maple Systems Inc All rights reserved Maple Systems Inc 808 134 th Street SW Suite 120 Everett WA 98204 7333 Phone 425 745 3229 Email maple maplesystems com Web www maplesystems com...

Reviews: