![Manufacturas Lenin MLR NSF User Manual Download Page 5](http://html.mh-extra.com/html/manufacturas-lenin/mlr-nsf/mlr-nsf_user-manual_1723955005.webp)
GAS INSTALLATION
A high pressure regulator, model 10-080, with a pressure gauge (0-7 Kg) must be
installed at the outlet of the gas tank in order to verify the correct supply pressure. The
pipe used for the connection is ½ inch in diameter, either type L copper or black ced
tube. 40
The length of the pipe should not exceed 10 meters, from the outlet of the gas tank. A
union nut must be installed between the stopcock and the low pressure regulator.
Before the machine, a low pressure regulator must be installed, changing the spring that
comes from the factory for a higher pressure one. After installation, the pressure
adjustment will be carried out by the Lenin Manufactures technician.
START UP
DANGER: the electrical power must be adequate for the proper functioning of the
tortilla machine, as the case may be, three-phase or single-phase.
WARNING: do not obstruct the muzzle with your hand, this may cause the flute to
explode.
ATTENTION: make sure that the griddles do not have objects on them. Wait 5 to 7
minutes for the comales to heat up.
A
AB
C
D
E
F
G
C
F
G
REGULATOR HIGH 10-080
STOP COCK AT 1.50 m (height)
1 "GALVANIZED PIPE
COPPER PIPE 1 "LP GAS
BLUE WOLF REGULATOR
STOP KEY
220 VOLTS (THREE PHASE OR
SINGLE PHASE AS THE CASE)
10 GAUGE CABLE (PIPE)
A
B
D
E