background image

 
 
 
 

 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

T24-ACMm & T24-BB1 

Acquisition Connectivity Module 
And Battery Box 

 
 

User Manual 
www.mantracourt.co.uk 

 

Summary of Contents for T24-ACMm

Page 1: ...T24 ACMm T24 BB1 Acquisition Connectivity Module And Battery Box User Manual www mantracourt co uk ...

Page 2: ...3 Connecting Input Signals to T24 ACMm 3 Using Completion Resistors 4 Half Bridge 4 Quarter Bridge 5 Specifications 5 General Radio 5 T24 ACMi 5 Approvals 6 CE 6 FCC 6 Industry Canada 7 OEM Reseller Marking and Documentation Requirements 7 FCC 7 IC 7 CE 7 Declaration of Conformity 9 Worldwide Regional Approvals 10 Warranty 10 ...

Page 3: ...s Getting Started The T24 ACMm requires that the acquisition module is factory fitted therefore this requires specifying at the time of ordering Opening the Case The case lid is secured with 2 x Philips head screws remove the screws and the case will come apart Connecting Power Power is supplied by fitting 2 X AAA cell 1 5 Volt batteries as directed inside the T24 BB1 Note there is no reverse pola...

Page 4: ...ere may be additional input wiring requirements so please refer to the acquisition module manual Acquisition Module Screw Terminal Function 5 Excitation 6 Signal 7 Signal T24 SAi T24 SAFi 8 Excitation Acquisition Module Screw Terminal Function 5 Excitation 6 V in 7 V in T24 VAi 0 10V 8 Excitation Acquisition Module Screw Terminal Function 5 Excitation 6 I in 7 I in T24 IAi 0 20mA 4 20mA Calibrated...

Page 5: ...hree completion resistors are located as shown below If using a half bridge only R1 and R2 need to be fitted we recommend low drift precision resistors to ensure reading stability typically 0 1 5ppm o C If using a quarter bridge R1 R2 and R3 must be fitted R3 must be the same resistance as the single gauge being used in the quarter bridge The diagram below shows how you should wire for full half a...

Page 6: ...feet Channels DSSS 16 Maximum range achieved in open field site with T24 SA at a height of 3 metres above ground and T24 HS held at chest height pointing towards the T24 SA T24 ACMm Parameter Minimum Typical Maximum Units Battery Supply Voltage 2 1 3 3 6 Volts dc Operating Temperature Range 40 65 C Storage Temperature Range 40 85 C Environmental protection IP54 Check operating temperature batterie...

Page 7: ... Direttiva 1999 5 EC Nederlands Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijn 1999 5 EC Norsk Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU directiv 1999 5 EC Português Este equipamento satisfaz os requisitos essenciais e outras provisões da Directiva 1999 5 EC Suomalainen Tämä laite täyttää direktiivin 1999 5 ...

Page 8: ...erate the equipment In order to fulfil the certification requirements the OEM must comply with FCC regulations 1 The system integrator must ensure that the text on the external label provided with this device is placed on the outside of the final product 2 The acquisition modules with external antennas may be used only with Approved Antennas that have been tested by mantracourt IC Labelling requir...

Page 9: ...the following form If the CE marking is reduced or enlarged the proportions given in the above graduated drawing must be respected The CE marking must have a height of at least 5mm except where this is not possible on account of the nature of the apparatus The CE marking must be affixed visibly legibly and indelibly ...

Page 10: ...duct Range to which this declaration relates are in conformity with the appropriate standard EN 300 328 following the provisions of the Radio and Telecommunications Terminal Equipment Directive 1999 5 EC FCC CFR Title 47 part 15c BS EN 61000 4 2 and BS EN 61000 4 3 following the provisions of the EMC Directive 2004 108 EC and Low Voltage Directive 2006 95 EC December 2007 Brett James Development M...

Page 11: ...problem If it is necessary to return the product to Mantracourt please include a note stating name company address phone number and a detailed description of the problem Also please indicate if it is a warranty repair The sender is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit Mantracourt warranty does not apply to defects resulting from act...

Reviews: